6. Data Recording
MTS-600 can store the measurement data ( including distance, angle, coordinate ),
station point data ,backsight direction angle data in the internal memory of
instrument. A total of 50000 points can be stored.
After power on, press [MENU] key on the panel to
enter main menu of the instrument.
Press [F1] in the main menu to enter Recording data
mode.
6.1Select a JOB for recording data
Before starting measurement and recording data ,a JOB should be selected at first.
①
Input the JOB
’
s name, then press [OK].
If the JOB already exists in the memory, then it will
be selected as the current JOB for recording data, or
the instrument will ask you if a new job should be
created.
l
Press [LIST] to display JOB list in the memory, and select a JOB from the
list.
②
Press [YES] to create a new JOB and enter
<Recording Data> menu.
l
The current JOB can be selected in Memory
management also, please see
“
7.1.2 Select a
JOB
”
.
6.2 Set instrument station and record the station data
Station point and direction angle data are the same in data recording mode and
normal coordinate measurement mode, and can be entered or changed.
①
Press [F1] in <Recording Data> menu to select
“
Station data
”
。
②
Input coordinates of the current station, then press
[REC].
MENU <1/2>
F1-Recording data
F2-Memory manager
F3-Communication
Select A JOB
JOB name
:
JOB001
123/ABC
LIST
OK
Creat JOB001?
NO
YES
Recording Data <1/2>
F1-Station data
F2-STN orientation
F3-Start measuring
N0(m)
:
0.000
E0(m)
:
0.000
Z0(m)
:
0.000
READ
REC
OK