MTS600 Instruction Manual
25
NOTE
:
l
In short distance measurement, even though the center of the reflective prism
and the reticle are slightly misaligned,
“
*
”
will be also displayed, but in fact,
accurate measurement is impossible. Therefore make sure that the target is
sighted correctly.
4.2.3 Distance and angle measurement
MTS-600 can measure both distance and angle data at the same time. Please get
confirmation again before measuring:
l
The instrument leveled and centered well.
l
Battery full charged.
l
The atmosphere correction and the prism constant are set correctly.
l
Prism center is already collimated and returned signal strength is suitable
①
In the distance measurement mode, press [MEAS]
or press the key [DIST] on the panel to start
measurement. When measurement starts, EDM
information (distance measuring mode, prism constant
value, atmospheric correction value)is displayed.
After a short time, a short beep sounds, and the
measured distance data, vertical angle ,and horizontal
angle data are displayed
.
②
Press [STOP] to stop measuring distance and return
to the distance measurement mode screen. If the single
measurement
mode
is
selected,
measurement
automatically stops after a single measurement.
During fine average measurement, the average value of the distance is displayed.
and on the right side of the screen the number of the measuring times is displayed
also. When the measuring times reach pre-determined number, the measurement
will stop automatically.
Psm.const. -30
Atmos.crn. 0ppm
Meas.mode Fine R
STOP
H.dist 165.274m
V.ang(Z) 92
°
55
′
39
″
H.ang(R) 90
°
15
′
00
″
STOP
H.dist 165.274m
V.ang(Z) 92
°
55
′
39
″
H.ang(R) 90
°
15
′
00
″
MEAS
DISP
MODE
EDM
OUTP