4.2.4 Distance measurements display switch
In the distance measure mode, the display can be shown in the following three
combination.
(1) horizontal distance ,vertical angle, horizontal angle
(2) horizontal distance, height difference, horizontal angle
(3) slope distance, vertical angle, horizontal angle
①
In the distance measurement mode, press [DISP] to
display the horizontal distance, height difference,
horizontal angle
②
Press [DISP] again, switch to display the slope
distance, vertical angle, horizontal angle
③
Press [DISP] once again,return to the original
display.
l
When the instrument was shipped from the
factory, the default display is the horizontal distance ,vertical angle,
horizontal angle .if you want to set other combinations , please see
“
10.
Setting parameters of instrument
”
4.2.5 Outputting distance measurement data
The measured distance and angle data can be output to a peripheral equipment
such as computer. Before carrying out this function, you should connected the
instrument and the peripheral equipment using serial communication cable, and set
communication parameters correctly, please see
“
10. Setting parameters of
instrument
”
①
Collimate the target point, measure the distance to the point.
②
After measurement is complete, Press [OUTP] to output the measurement
data to computer or other peripheral equipment.
Caution
:
l
This function only outputs the slope distance, vertical angle, horizontal
angle.
H.dist 165.274m
V.dist -9.387m
H.ang(R) 90
°
15
′
00
″
MEAS
DISP
MODE
EDM
OUTP
S.dist 189.516m
V.ang(Z) 92
°
55
′
39
″
H.ang(R) 90
°
15
′
00
″
MEAS
DISP
MODE
EDM
OUTP
H.dist 165.274m
V.ang(Z) 92
°
55
′
39
″
H.ang(R) 90
°
15
′
00
″
MEAS
DISP
MODE
EDM
OUTP