MTS600 Instruction Manual
67
②
Press [F1] to select "With psm.ht input ".
③
Input the prism height and press [OK]. The
procedure prompts measuring the prism first.
l
Press [MODE] to select distance measuring
mode.
l
Press [EDM] to check returned signal, set the atmosphere correction and the
prism constant, please see
“
4.2 distance measurement
”
.
④
Collimate the center of the prism, press [MEAS] to
start measurement. When measurement is complete,
the results are displayed.
⑤
Press [OK]. The REM measurement is started.
Sight the object, the height from the ground to the
object is displayed. While rotating the telescope, the
height are calculated and displayed in real time.
l
Press [MEAD] to re-observe the prism.
l
Press [PSMH] to reenter the prism height.
l
Press [STOP] to stop REM measurement.
9.4.2 Without prism height input
①
Place the prism directly under or directly over the
object. In the second page of <Program> menu,
press [F1] to select "REM".
②
Press [F2] to select "Without psm.ht input".
③
Collimate the center of the prism, press [MEAS] to
start measurement. When measurement is complete,
the results are displayed.
REM
Psm.ht(m)
:
0.000
OK
V.ang(Z) 88
°
40
′
42
″
H.ang(R) 45
°
23
′
07
″
Collimate psm. and meas.
MODE EDM CE MEAS
*H.dist 165.274m
*V.ang(Z) 91
°
55
′
37
″
*H.ang(R) 40
°
15
′
00
″
CE OK
REM
Elev 3.468m
V.ang(Z) 90
°
33
′
17
″
STOP PSMH MEAS
Select REM Mode
F1-With psm.ht input
F2-Without psm.ht input
V.ang(Z) 88
°
40
′
42
″
H.ang(R) 45
°
23
′
07
″
Collimate psm. and meas.
MODE
EDM
CE
MEAS
*H.dist 165.274m
*V.ang(Z) 91
°
55
′
37
″
*H.ang(R) 40
°
15
′
00
″
CE OK