l
Pressing [DIFF]can see the difference between
the current coordinate and the setting-out
coordinate.
⑦
Observe the height difference between the target
and the required point which displayed on the third
line.
:
move the prism upward.
:
move the prism downward.
Move the prism upward and downward until the value displayed on the
fourth line is 0m.
When the height difference approach 0m
,
two arrows will be displayed
When all the values displayed on the screen are 0,then the setting-out point
is just located at the bottom of the pole that the prism attached to
⑧
Press [DIFF] to see the difference between the
current coordinate and the setting-out coordinate.
Press [ESC] to finish this point setting-out
measurement and continue the next point.
Distance scale correction in the coordinates setting-out measurement.
MTS-600 can carry out the distance correction of Average Elevation and
Projection by setting a scale factor .In the second page of menu
<
S-O
Coordinate
>
,Press [F1] to select "Scale correction", and enter correction factor.
l
Distance scale correction also can be set in parameter setting mode, please
see "10. setting parameter of instrument".
l
For details about distance scale correction, please see "10. setting
parameter of instrument".
dHA 0
°
00
′
00
″←
→
dHD 0.000m
↑↓
dHT -4.723m
MODE
EDM
HSET
DIFF
MEAS
dHA 0
°
00
′
00
″←
→
dHD 0.000m
↑↓
dHT 0.001m
MODE
EDM
HSET
DIFF
MEAS
dN 0.000m
dE -0.000m
dZ 0.001m
MODE
EDM
HSET
←↓→↑
STOP