MTS600 Instruction Manual
60
①
In <Program> menu, press [F2] to select
“
Offset
measurement
”
, The procedure prompts measuring the
offset point first.
l
Press [MODE] to select distance measuring
mode.
l
Press [EDM] to check returned signal, set the atmosphere correction and the
prism constant, please see
“
4.2 distance measurement
”
②
Collimate the offset point, press [MEAS].The
instrument starts measuring the offset point and
display the result.
③
Press [OK]. Procedure request selecting offset
mode.
④
Press [F1] to select
"Distance". Procedure request
inputting the direction of offset point and horizontal
distance from the target point to the offset point.
l
Press [MEAS] to re-observe the offset point.
⑤
Press [DIREC] to select the direction of the offset
point.
l
↑
Forward
:
Closer than the target point.
l
↓
Rear
:
Beyond the target point.
l
←
Left
:
On the left of the target point.
l
→
Right
:
On the right of the target point.
⑥
Example: if the offset point on the left of the target
point. Press [F3] to select "Left".
V.ang(Z) 88
°
40
′
42
″
H.ang(R) 45
°
23
′
07
″
Meas.offset point
MODE EDM CE MEAS
*H.dist 165.274m
*V.ang(Z) 91
°
55
′
37
″
*H.ang(R) 40
°
15
′
00
″
CE OK
Select Offset Mode
F1-Distance
F2-Angle
Input Offset Data
Direc
:↑
Forward
Dist(m):
0.000
MEAS DIREC OK
Offset Pt. Direc. <1/2>
⊙
F1--Forward
○
F2--Rear
○
F3
—
Left
Input Offset Data
Direc
:
←
Left
Dist (m):
0.000
MEAS DIREC OK