MTS600 Instruction Manual
24
mode is set, the instrument measures the distance as the setting times and the
average distance will be displayed. The number of measuring times can be
defined by the user.
Example 1: Set distance measuring mode as Tracking
mode.
Press [MODE] in the distance measurement mode to
come in distance measuring mode setting screen.
Press [F3] to complete the setting and exit.
Example 2:Set distance measuring mode as Fine Ave
mode, and measuring times as four.
①
Press [F5] to get to the second page of the distance
measuring mode setting, press [F2] to select the Fine
Ave mode.
②
Input measuring times
“
4
”
,press [OK] to complete
setting and exit.
4.2.2 Returned signal checking
This function is used to check if sufficient reflected light is returned by the
reflective prism sighted by the telescope. When the target is in long distance,
difficult to sight, this function is helpful in seeking
and sight the target.
①
In the distance measurement mode, press [EDM].
②
When returned light is received, the buzzer will
sound and the strength of light is displayed.
if
“
*
”
is displayed, it indicates that enough light for
the measurement is returned, then pressing [MEAS]
can start measuring the sighted target.
Dist.Meas.Mode <1/2>
⊙
F1
—
Fine S
○
F2
—
Rapid S
○
F3
—
Tracking
Dist.Meas.Mode <2/2>
○
F1
—
Fine R
○
F2
—
Fine Ave
Dist.Meas.Mode
Average times
:
5
OK
Psm.const. -30
Atmos.crn. 0ppm
Signal
BEEP
PC
PPM
MEAS
Psm.const. -30
Atmos.crn. 0ppm
Signal
*
BEEP
PC
PPM
MEAS