MTS600 Instruction Manual
20
4.1.5 Horizontal angle repetition
To find the horizontal angle with greater precision, perform repetition
measurement.
Instrument Station
1st meas.end(the angle is displayed)
2nd meas.Starts
3rd meas.Starts
2nd meas.end(average of two measurements is displayed)
3rd meas.end(average of three measurements is displayed)
1st meas.Starts
1st Target(BS)
2nd Target(FS)
①
Press [REP] in the second page of angle
measurement mode to begin with the angle repetition
measurement.
②
Collimate the first target and press [OK].
③
Collimate the second target and press [OK]. The
included angle between two target points is displayed.
l
Press [CE] to cancel last measurement and redo it.
④
Re-collimate the first target, and press [OK].
⑤
Re-collimate the second target, press [OK],
The added value of the horizontal angle and the
average value of the horizontal angle are displayed.
The times of measurement is displayed also. Repeat
the step 2,3, and continue the measurement. When the measurement is complete,
Total 0
°
00
′
00
″
Ave. 0
°
00
′
00
″
Collimate 1st target
CE
OK
Total 0
°
00
′
00
″
Ave. 0
°
00
′
00
″
Collimate 2nd target
CE
OK
Total 54
°
30
′
16
″
/1
Ave. 54
°
30
′
16
″
Collimate 1st target
CE
OK
Total 54
°
30
′
16
″
/1
Ave. 54
°
30
′
16
″
Collimate 2nd target
CE
OK
Total 54
°
30
′
16
″
/2
Ave.54
°
30
′
16
″
Collimate 1st target
CE
OK