MTS600 Instruction Manual
17
4. Basic measurement
Basic measurement includes angle measurement, distance measurement,
coordinate measurement.
4.1 Angle measurement
l
Before the measurement, please inspect once more and make sure the
instrument is leveled and centered precisely.
After power on, press [ANG] key on the panel to enter
the angle measurement mode, carrying on the function
related to measurement of angle . The function
allocated at two pages, can be switched by pressing
[> > ].
4.1.1 Measuring the horizontal angle between two points
Use the
“
0 SET
”
function to measure the included angle between two points.
①
Collimate the first target
,
Press [0SET] in the first
page of the angle measurement mode screen.
②
Press [OK], the target direction's horizontal angle
is set as 0
°
00 ' 00 "
③
Collimate the second target, the horizontal angle
displayed is the included angle between two target
points (56
°
47
′
35
″
).
V.ang(Z) 92
°
24
′
18
″
H.ang(R) 65
°
43
′
13
″
OSET
R/L
HSET
A/%
>>
H.angle 0 set
H.ang(R) 0
°
00
′
00
″
Collimate target
CE
OK
V.ang(Z) 92
°
24
′
18
″
H.ang(R) 0
°
00
′
00
″
OSET
R/L
HSET
A/%
>>
V.ang(Z) 92
°
24
′
18
″
H.ang(R) 56
°
47
′
35
″
OSET
R/L
HSET
A/%
>>