![LeCroy WaveRunner 6Zi Getting Started Manual Download Page 92](http://html1.mh-extra.com/html/lecroy/waverunner-6zi/waverunner-6zi_getting-started-manual_1866372092.webp)
Getting Started Manual
WR6Zi-GSM-E
82
Width Condition is
Width
triggers (and other triggers equipped with conditional logic) have
conditional logic settings as follows.
Your
Width Condition
can be specified as
Less Than
,
Greater Than
,
In
Range
and
Out Of Range
.
In Range
and
Out Of Range
conditions can be further set with
Upper
and
Lower Values
(for
Limits
).
OR
Nominal width
and
Delta
(for
Delta
).
Note
: Width Condition settings are summarized on the far right of the
dialog.
Holdoff by Time or Events
Holdoff is an additional condition of Edge and Pattern triggers. It can be
expressed either as a period of
time
or an
event
count. Holdoff disables
the trigger circuit for a given period of time or number of events after
the last trigger occurred. Events are the number of occasions on which
the trigger condition is met. The trigger resumes when the holdoff has
elapsed and its other conditions are met.
Select the holdoff by touching the
Time
or
Events
buttons on the
Holdoff
dialog.