1—1
Page 3
AP101B-7200-15
Electrical System
AC Power Supplies
10. A G4B compass system requires 115 volt single phase AC power
supplied by a rotary inverter under the Navigator’s table. Power for the
inverter is through a circuit breaker in the MEP. Control of the inverter
is by two buttons on the Navigator’s panel, marked ON and OFF. An
associated doll’s eye indicates when the inverter is running.
Distribution
11. The starter motors, feathering pumps and inverter are supplied through
their associated relays. The main electrical panel CBs are listed in Table 1.
Table 1 - Main Electrical Panel
CB
Number
Rating
Service
System
1
10
No. 1 FIRE EXT
FIRE
2
10
No. 2 FIRE EXT
3
10
No. 3 FIRE EXT
4
10
No. 4 FIRE EXT
5
5
No. 1 FIRE WARN
6
5
No. 2 FIRE WARN
7
5
No. 3 FIRE WARN
8
5
No. 4 FIRE WARN
9
5
No. 1 RAD SHUTTER
ENGINE
&
FUEL
10
5
No. 2 RAD SHUTTER
11
5
No. 3 RAD SHUTTER
12
5
No. 4 RAD SHUTTER
13
10
No. 1 PROP FEATHER
14
10
No. 2 PROP FEATHER
15
10
No. 3 PROP FEATHER
16
10
No. 4 PROP FEATHER
17
10
No. 1 PORT FUEL PUMP
18
10
No. 2 PORT FUEL PUMP
UNCONTROLLED DOCUMENT - NOT FOR USE IN FLIGHT OR TO BE PRINTED
UNCONTROLLED DOCUMENT - NOT FOR USE IN FLIGHT OR TO BE PRINTED