
6 | Function description
The user interface
6.4.4.2 The parameter window [Data table]
In the parameter window [Data table] you can specify which values to display in the
window [Online-HR 600]. The display of the diagram itself may be adjusted to your
requirements in the [Display properties] dialog. With regard to this, please read the
chapter The window [Online HR 600] [
85].
ü
To display the [Data table] parameter window:
a) Enable the [Data table] tab:
Actual parameters
Data table
System settings
System info
Soldering
Placement
Profile library
Archive
Save target position
Data table
System ready
Sensor
Temp
Measuring side
Measuring position
Board
Component
Show
Colour
Weight
IRS
TC1
TC2
TC TOP
Top center
Outside top
Bot left
Center bottom
Right bottom
Fan:
---
21,5 °C
---
---
0%
0%
---
0%
0%
100%
Top side
Top side
Top side
Top side
Top side
Top side
Top side
Top side
Top side
Top side
Top center
Top center
Top center
Top center
Top center
Top center
Top center
Top center
Top center
Top center
X-Axis
Y-Axis
Z-Axis
Angle of rotation
-86765
149787
0
0
Fig. 23:
The [Data table] parameter window
To display measured values:
ü
Select which measured values you want to display in the window [Online-HR
600]:
a) In the [Show] column, enable the checkbox of a measured value.
The measured value is displayed in the [Online-HR 600] window. These settings are
not linked to a profile.
To customize the graphical representation:
ü
To customize the graphical representation in the [Online-HR 600] window:
a) In the [Colour] column, click on the colour field of a measured value, then se-
lect the colour in the [Colour] dedicated window.
b) Click the [Weight] field of a measured value in the [Weight] column, and then
choose a thickness value [1], [2] or [3] from the displayed menu.
Description of the sensor types:
[IRS] = Infrared radiator sensor
[TE1] / [TE2] = Thermocouple 1 (TC1) and 2 (TC 2)
[Ostr] = Top radiator sensor is the thermocouple in heating head
[Top centre / Top outside] = sensors of the top radiators: in the middle and outside
[Bot] = Sensors of the bottom radiators: left/centre/right
[Fan] = fan sensor (only above)
Ersa GmbH
3BA00207_01 Operating Instructions HR 600_2 | Rev. 3
81 / 169