6 | Function description
Working with the HR 600/2 unit
To customize the control ratio between upper radiator/lower radiator:
You can change the power ratio:
– [TOP-based] (100%, heat only the upper radiator)
– [balanced] (50%, heat upper and lower radiators equally)
– [BOT-based] (0%, heat only the lower radiator)
In between, control conditions can be set with 1%-increments.
ü
To customize the control ratio:
a) Move the slider [Heater balance] up or down.
ð
In the display panel below the slider, you can read the value set, or enter a
value.
ü
Saving changes:
a) Click on the [OK] button.
ð
Settings have been applied, the window is closed.
ü
Cancelling the operation:
a) Click on the [Cancel] button.
ð
The window is closed. No changes have been applied.
ü
To restore the factory settings:
a) Click on the [Default] button.
ð
The factory setting is restored:
– Fan power: 50%
– All the radiators are active
– Lower radiator power: 100%
– Control ratio 50 [balanced]
Displaying the help function:
a) Click on [Help], or press the [F1] key on the keyboard.
ð
The online help is displayed.
To transfer the [time 1] configuration to other areas:
ü
Copy the [Configuration] of [time 1] to the [time 2], [time 3] and [time 4] areas:
a) Click on [Configuration] in the [Copy to all zones] window.
ð
The settings of the [time 1] area are copied to all areas.
To save changes in the profile:
a) Click on the [Profile parameters] button in the [Overwrite] frame.
ð
Changes are saved in the profile.
Ersa GmbH
3BA00207_01 Operating Instructions HR 600_2 | Rev. 3
116 / 169