Kramer Electronics Ltd.
VS-1616DN-EM
– Using the Configuration Menus
25
4. Using the numeric keys, enter the input in which to store the EDID (in this example, 08),
and enter the output (in this example, 05) from which to read the EDID.
The following is displayed:
01 02 03 04 05 06 07 08
05 out05 => in08
The TAKE button flashes.
5. Repeat Step 4 for up to eight inputs.
6. Press TAKE.
The EDID is stored and passed through to the input.
The display reverts to the output/input display.
To view the EDID assignments:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID) on the numeric keypad (see
The following is displayed:
SETUP EDID
ENTER to View EDID and Set EDID
3. Press ENTER.
The current EDID matrix configuration is displayed. In this example, input 07 is assigned
to output 05, all other EDID values are default.
05 06 07 08 09 10
05
Setup Menu
—
9: Delay, Setting for an Output
This option sets the time delay for an output which lapses between entering a switching action
and the execution of the action. This delay can be set for each output independently. The
delay is defined in units of 200ms and ranges from 0 to 15, providing delays of between 0 and
3 seconds (15 x 200ms = 3 seconds).
To set the execution delay for an output:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 9 (DELAY) on the numeric keypad (see
The output/delay times display is shown.
3. Using the numeric keys, enter the output (in this example, 03).
The following is displayed:
01 02 03 04 05 06 07 08
DLY__ =>out03
4. Using the numeric keys, enter the number of delay units.
5. Press TAKE.