Kramer Electronics Ltd.
VS-1616DN-EM
– Protocol 3000
139
PRST-LST
Functions
Permission
Transparency
Set
-
-
-
Get
PRST-LST?
End User
Public
Description
Syntax
Set
-
-
Get
Get list of saved presets
#
PRST-LST?
CR
Response
~nn@
PRST-LST
SP
preset,preset,…
CR LF
Parameters
preset
– preset number:
1-60
Response Trigger
Notes
In most units, video and audio presets with the same number are stored and recalled together by
commands
#PRST-STO
and
#PRST-RCL
K-Config Example
“#PRST
-
LST?”,0x0D
PRST-RCL
Functions
Permission
Transparency
Set
PRST-RCL
End User
Public
Get
-
-
-
Description
Syntax
Set
Recall (load) a saved preset
#
PRST-RCL
SP
preset
CR
Get
-
-
Response
~nn@
PRST-RCL
SP
preset
CR LF
Parameters
preset
– preset number:
1-60
Response Trigger
Notes
In most units, video and audio presets with the same number are stored and recalled together by
commands
#PRST-STO
and
#PRST-RCL
K-Config Example
Recall previously saved connections, volumes, and modes (audio and video routing table) from preset 5:
“#PRST
-
RCL 5”,0x0D