Kramer Electronics Ltd.
VS-1616DN-EM
– Using the Configuration Menus
30
2. Press MENU until a display is shown similar to the following:
OUT: 01 02 03 04 05 06 07 08 09 10 11
SET: o
o
X
X
o
o
o
o
X
X
X
X
indicates that there are no modifiable parameters for the associated port and
o
indicates
that there are modifiable parameters for the associated port.
3. Press TAKE to enter the list of ports.
The cursor flashes on a selected port.
4. Select the required port to modify using the left and right arrow buttons.
5. Press TAKE to enter the parameters list.
A message similar to the following is displayed with the relevant port number in place of
06:
OUT: 06
SET: Reset SubBoard
6. To select the next parameter press the right arrow button (see
Or:
7. To enter the displayed parameter press TAKE.
The parameter options are displayed.
8. Select the required action or number using the keypad numbers and arrows.
9. Press TAKE to save the change.
The parameter change is not implemented on the system until you press TAKE.
10. Repeat from Step 6 to modify other parameters.
11. Do one of the following:
▪
Press BREAKAWAY to exit the Config Menu.
▪
Wait approximately 15 seconds for the operation to time out.
▪
Press MENU to exit to the parameter list.
Config Menu
—
Store Default Setup
This option lets you store the current setup as the default setup. The default setup can be
recalled at any time using the DEFAULT SETUP button (see
This is not the setup that is loaded when the unit is switched on.
To store the current setup as the default setup:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENTER to change them