Kramer Electronics Ltd.
VS-1616DN-EM
– Using the Configuration Menus
24
2. Press 1 (ALL) on the numeric keypad (see
The following is displayed:
in__ => ALL
3. Using the numeric keys, enter the input to be switched to all outputs.
The TAKE button flashes.
4. Press TAKE.
The selected input is switched to all outputs. The display reverts to the output/input
display showing that the selected input is switched to all outputs.
Setup Menu
—
3: outXX=>OFF, Turning an Output Off
This option turns an output off.
To turn an output off:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 3 (OFF) on the numeric keypad (see
The following is displayed:
out__ => OFF
3. Using the numeric keys, enter the output to be turned off.
The TAKE button flashes.
4. Press TAKE.
The selected output is turned off. The display reverts to the output/input display showing
that the selected output is turned off with the input being blank.
Setup Menu
—
7: EDID, Assignment to an Input
This option assigns an EDID to between one and eight inputs in non-volatile storage. More
than eight EDID assignments must be assigned in multiple batches.
Each input on the
VS-1616DN-EM
has a factory default EDID loaded (see
). The EDID for each input can be changed independently via the menu
(described below) or by uploading an EDID binary file to each input via the RS-232 port.
It is necessary to have a display/device connected to the output from which you want to read
the EDID. Failure to do so results in the default EDID being written to storage.
To assign an EDID to between one and eight inputs:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID) on the numeric keypad (see
The following is displayed:
SETUP EDID
ENTER to View EDID and Set EDID
3. Press ENTER.
The current EDID matrix configuration is displayed.