Kramer Electronics Ltd.
VS-1616DN-EM
– Protocol 3000
146
H-PHASE
Functions
Permission
Transparency
Set
H-PHASE
End User
Public
Get
H-PHASE?
End User
Public
Description
Syntax
Set
Set H-Phase value
#
H-PHASE
SPstage,channel,valueCR
Get
Get H-Phase value
#H-PHASE
?
SPstage,channelCR
Response
~nn@
H-PHASE
SPstage,channel,valueCR LF
Parameters
stage
–
1/IN
(input),
2/OUT
(output)
channel
– input or output number:
1-16
(varies according to installed input / output cards, see
value
– H-Phase value in Kramer units:
0-63
,
++
(increase current value),
--
(decrease current value)
Response Trigger
Notes
A minus sign precedes negative values
This command is only valid for VGA cards
K-Config Example
Set the H-Phase value of output 8 to 60:
“#H
-
PHASE 2,8,60”,0x0D
Increase the H-Phase value of input 5 by 1 unit:
“#H
-
PHASE 1,5,++”,0x0D