Ch.1 Before Installation
< 13 >
DRYPRO MODEL 771 INSTALLATION MANUAL Ver.1.00 2003.10
Basic/Expansion Port Configurations Judgement Flow
Flowchart to help judge whether to select basic configuration or expansion port configuration is set out below.
Connecting with
5 or more external
devices
Connecting with
8 or less external
devices
2 or more devices
allocated to
expansion port
5 or less devices
allocated to
expansion port
3 or less devices
not allocated to
expansion port
Connect to one
DRYPRO 771 with
expansion
port configuration
Install 2 or more DRYPRO
771 and allocate the external
device between the two.
Connect to one DRYPRO
771 in basic configuration
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
Configure so that the 3
devices are not allocated
to the expansion port.
Select the basic configuration when it is possible to secure sufficient space for
installing several units of DRYPRO 771.
Conditions required for the device to be allocated to the expansion port.
• KDIS devices (RS Series, IS Series, Liteview) or REGIUS Series (only for back up
set up)
• Film sheets to be printed per day is 20 or less.
• LUT is fixed to linear. Setting of PRINT CONDITION("S20", "U30") is used
commonly for the expansion 5ch.
Summary of Contents for DRYPRO 771
Page 10: ...Preface 8 DRYPRO MODEL 771 INSTALLATION MANUAL Ver 1 00 2003 10...
Page 26: ...Ch 1 Before Installation 24 DRYPRO MODEL 771 INSTALLATION MANUAL Ver 1 00 2003 10...
Page 54: ...Ch 2 Unpacking and Installation 52 DRYPRO MODEL 771 INSTALLATION MANUAL Ver 1 00 2003 10...
Page 82: ...Ch 4 Checking the Image 80 DRYPRO MODEL 771 INSTALLATION MANUAL Ver 1 00 2003 10...
Page 96: ...Ch 4 Checking the Image 94 DRYPRO MODEL 771 INSTALLATION MANUAL Ver 1 00 2003 10...