Field Service Ver. 2.0 Mar. 2006
6. Periodical check
21
bizhub C250P
Maintenance
6.
Remove the Bypass Tray Feed Roller
[8].
7.
To reinstall, reverse the order of
removal.
8.
Select [Service Mode]
→
[Counter]
→
[Life] of the Jig software and clear
the count of [Manual Tray].
NOTE
• Replace the Bypass Tray Feed
Roller and the Bypass Separation
Roller Assy at the same time.
6.5.4
Replacing the Bypass Tray Separation Roller Assy
1.
Remove the Multi Bypass Unit.
See P.100
2.
Remove the Screw [1], and remove
the Ground terminal [2].
3.
Remove the Screw [3], and remove
the Bypass Paper Separation Roller
Assy [4].
[8]
4038F2C008DB
[1]
[2]
4038F2C009DA
[3]
[4]
4038F2C010DA
bizhub_C250P_Total.book 21 ページ 2006年3月27日 月曜日 午前8時28分