Field Service Ver. 2.0 Mar. 2006
11. Other
101
bizhub C250P
Maintenance
11.3.24
PH Unit
A. Removal Procedure
1.
Remove the Front Cover.
See P.81
2.
Remove the Image Transfer Belt Unit.
See P.32
3.
Remove the Screw [1] and discon-
nect the Connector [2] respectively,
and remove three Imaging Unit
Guide rails [3].
4.
Disconnect the Flat Cable [4] and the
Connector [5] of the PH Unit (Black).
5.
Unhook the tab [6], and remove the
Gear [7] of the PH Unit (Black).
[1]
[2]
[3]
4038F2C106DA
[4]
[5]
4038F2C107DA
[7]
[6]
4038F2C108DB
bizhub_C250P_Total.book 101 ページ 2006年3月27日 月曜日 午前8時28分