16. TECH. REP. MODE
Field Service Ver. 2.0 Mar. 2006
198
bizhub C250P
Adjustment / Setting
16.4.3
Software SW setting for CS Remote Care
NOTE
• SW bits data are written into the NVRAM every time a change is made. In case you
changed bit data by accident, be sure to restore the previous state.
A. Input procedure
1.
Select [Tech. Rep. Mode]
→
[CS Remote Care]
→
[Detail Setting: ***], and select [Soft-
ware Switch Setting]. (***: modem or e-mail)
2.
Select [Switch No.], and input the SW number (two digits) using the 10-Key Pad.
3.
Select [Bit Assignment], and select SW bit number using the arrow keys, and input 0 or
1 using the 10-Key Pad.
(For setting by hexadecimal numbers, select [HEX Assignment], and input using the 1-
Key Pad or A to F keys.)
4.
Press the Menu/Select key.
NOTE
• About functions of each switch, see to “B.List of software SW for CS Remote
Care.”
B. List of software SW for CS Remote Care
NOTE
• Do not change any bit not described on this table.
SW No.
Bit
Functions
0
1
Default
SW 01
0
Dial Mode
Pulse
Tone
1
1
Reservation
—
—
0
2
Reservation
—
—
0
3
Reservation
—
—
0
4
Baud rate
*1
*1
0
5
*1
*1
0
6
*1
*1
0
7
*1
*1
1
SW 02
0
Auto call on SC occurrence
Do not call
Call
1
1
Auto call on date specification
Do not call
Call
1
2
Reservation
—
—
0
3
Reservation
—
—
0
4
Reservation
—
—
0
5
Auto call on the IC Life
Do not call
Call
1
6
Auto call on CCD Clamp/Gain
Adjustment failure
Do not call
Call
1
7
Reservation
—
—
0
SW 03
0
Reservation
—
—
0
1
Auto call on the toner supply
Do not call
Call
1
2
Reservation
—
—
0
3
Auto call on the waste toner bottle full
Do not call
Call
1
4 to 7 Reservation
—
—
0
SW 04
0 to 7 Reservation
—
—
0
1
1
FS3.fm 198 ページ 2006年3月27日 月曜日 午前9時3分