23. Malfunction code
Field Service Ver. 2.0 Mar. 2006
308
bizhub C250P
T
roubleshooting
23.3 Call Service (Trouble Code)
• Machine status will be self diagnosed by CPU circuit. The Trouble Code will be displayed
on the control panel when the error is detected.
23.3.1
Call Service list
* For the details of the Call Service of the options, see the Service Manual for the corre-
sponding option.
4038F4E522DA
Call Service will be displayed
Ready to print LED will be OFF
Error LED will be ON
Trouble C-xxxx
Call Service
Code
Item
Description
Rank
C0001 LCT Connection failed
See PC-403 Service Manual.
B
C0102 LCT Vertical Transport Motor
malfunction
B
C0204 Tray 2 Elevator failure
• The Lift-Up Sensor is not blocked even after the
lapse of a given period of time after the lifting
motion has been started.
B
C0206 Tray 3 Elevator failure
See PC-103/PC-203 Service Manual.
B
C0208 Tray 4 Elevator failure
B
C0209 LCT Elevator Motor malfunction
(Elevator malfunction)
See PC-403 Service Manual.
B
C0210 LCT ascent motion failure
B
C0211 Manual Tray Rise Descent Error • The Bypass Lift-Up Sensor is not blocked even
when the Tray 2 Vertical Transport Motor has
turned for a given number of pulses after the
sequence to move the Paper Lifting Plate from the
standby position to the feed position was started.
• The Bypass Lift-Up Sensor is not unblocked even
when the Tray 2 Vertical Transport Motor has
turned for a given number of pulses after the
sequence to move the Paper Lifting Plate from the
feed position to the standby position was started.
B
C0212 LCT ejection failure
See PC-403 Service Manual.
B
C0213 LCT Shift Gate malfunction
B
C0214 LCT shifting failure
B
C0215 LCT Shift Motor malfunction
B
C0301 Suction Fan Motor's failure to
turn
• The Fan Lock signal remains HIGH for a predeter-
mined continuous period of time while the Motor
remains stationary.
B