Field Service Ver. 2.0 Mar. 2006
6. Periodical check
19
bizhub C250P
Maintenance
3.
Take off the rubber stopper [3], shaft
[4], spring [5], and guide plate [6] to
remove the Paper Separation Roller
fixing bracket Assy [7].
4.
Snap off the E-ring [8] and the Tray 1
Paper Separation Roller Assy [9].
5.
To reinstall, reverse the order of
removal.
6.
Select [Service Mode]
→
[Counter]
→
[Life] of the Jig software and clear
the count of [1st.].
NOTE
• Replace the Tray 1 Feed Roller and
Tray 1 Separation Roller at the
same time.
6.5.3
Replacing the Bypass Tray Feed Roller
1.
Remove the Multi Bypass Unit.
See P.100
2.
Snap off the E-ring [1], and remove
Bypass Paper Feed Clutch [2].
[3]
[7]
[6]
[4]
[5]
4038F2C003DB
4037F2C509DA
[8]
[9]
[1]
[2]
4038F2C004DA
bizhub_C250P_Total.book 19 ページ 2006年3月27日 月曜日 午前8時28分