Field Service Ver. 2.0 Mar. 2006
16. TECH. REP. MODE
185
bizhub C250P
Adjustment / Setting
16.3 Settings in Tech. Rep. Mode
16.3.1
Counter Reset
16.3.2
Running Mode
16.3.3
Option Board
Functions
• To check the number of hours or times each of the different maintenance parts has
been used.
• To clear the count of each counter.
Use
• When each of the maintenance parts is replaced.
Setting/
Procedure
• To clear the count of a counter, select the specific part and press the Clear key.
• If a counter is cleared mistakenly, press the Interrupt key, which will undo the clearing
operation.
• It is not possible to clear the count of the counters for the Fusing Unit, Transfer Belt
Unit, and IU, which are provided with a new unit detection function.
• ALL
: All counters
• Transfer Roller
: Number of times a sheet of paper is fed through
• Ozone Filter
: Number of times a sheet of paper is fed through
• Tray 1
: Number of sheets of paper fed from Tray 1
• Tray 2
: Number of sheets of paper fed from Tray 2
• Tray 3
: Number of sheets of paper fed from Tray 3
• Tray 4
: Number of sheets of paper fed from Tray 4
• Bypass
: Number of sheets of paper fed from the Bypass
• LCT
: Number of sheets of paper fed from LCT
• Finisher
: Number of sheets of paper fed out of the Finisher
Functions
• To test the printing operation in Running Mode.
Use
• Use to check the printing operation in Running Mode from each paper source.
Setting/
Procedure
1.
Display the Running Mode and click the Menu/Select key.
2.
Select the position for paper feed and click the Menu/Select key.
3.
Select the paper size and paper type.
4.
Press the Men/Select key to start the Running Mode.
5.
Pressing the Cancel key will stop operation.
Functions
• To set when the Optional HDD Kit, Local Interface Kit is mounted.
Use
• Use when setting up the HDD Kit, Local Interface Kit is mounted.
Setting/
Procedure
• Setting modes are HDD and local I/F.
• The default setting is “Unset.”
local I/F
: Set
“Unset”
HDD
: Set
“Unset”
NOTE
• When the setting has been changed, turn OFF and ON the Main Power Switch.
bizhub_C250P_Total.book 185 ページ 2006年3月27日 月曜日 午前8時28分