Field Service Ver. 2.0 Mar. 2006
17. Jig Soft
277
bizhub C250P
Adjustment / Setting
17.16.4
Forwarding Access Setting
A. User ID
B. Password
C. URL
D. FileName
NOTE
• It is not possible to set the start of downloading of Internet ISW from the Jig soft-
ware. Set the start from the control panel of the machine.
Functions
• To register the User ID for accessing the Program Server where Firmware is to be
stored.
Use
Setting/
Procedure
1.
Select [User ID].
2.
Enter the User ID (up to 64 one-byte characters) on the on-screen keyboard.
Functions
• To register the Password for accessing the Program Server where Firmware is to be
stored.
Use
Setting/
Procedure
1.
Select [Password].
2.
Enter the Password (up to 64 characters) on the on-screen keyboard.
Functions
• To register the Address and Directory of the Program Server where the Firmware is
to be stored in URL.
Use
Setting/
Procedure
1.
Select [URL].
2.
Enter the URL (up to 256 one-byte characters) on the on-screen keyboard.
NOTE
• Enter the URL which format suits the Protocol to be used.
When connecting to http http:// (Host name or IP Address)/ Directory name or
https:// (Host name or IP Address)/Directory name.
When connecting to ftp ftp:// (Host name or IP Address) / Directory name.
Functions
• To register the file name of the Firmware data to be downloaded.
Use
Setting/
Procedure
1.
Select [FileName].
2.
Enter the File Name (up to 63 one-byte characters) on the on-screen keyboard.
bizhub_C250P_Total.book 277 ページ 2006年3月27日 月曜日 午前8時28分