Field Service Ver. 2.0 Mar. 2006
18. Enhanced Security
279
bizhub C250P
Adjustment / Setting
18.3 Settings in the Enhanced Security
18.3.1
CE Password
18.3.2
Administrator Password
18.3.3
CE Authentication
18.3.4
IU Life Stop Setting
Functions
• To set and change the CE Password.
Use
• Use to change the CE Password.
Setting/
Procedure
• Enter the CE Password (8 digits) on the on-screen keyboard.
• The initial setting is “92729272.”
Current Password
: Enter the currently using CE Password.
New Password
: Enter the new CE Password.
Re-Input Password : Enter the new CE Password again.
NOTE
• When the following setting leads to the Password Rules [ON], the password
with the same letters as well as the password which is same as the previous
one cannot be changed.
[Admin. Setting]
→
[Security Setting]
• NEVER forget the CE password. When forgetting the CE password, call
responsible person of KONICA MINOLTA.
Functions
• To set and change the Administrator Password.
Use
• Use to change the Administrator Password.
Setting/
Procedure
• Enter the Administrator Password (8 digits) on the on-screen keyboard.
• The initial setting is “12345678.”
New Password
: Enter the new Administrator Password.
Re-Input Password : Enter the new Administrator Password again.
NOTE
• When the following setting leads to the Password Rules [ON], the password
with the same letters, the password which is same as the previous one and the
password of less than eight digits cannot be changed.
[Admin. Setting]
→
[Security Setting]
Functions
• To determine whether or not to authenticate CE Password as entering Service Mode.
Use
• Use when authenticating CE Password as entering Service Mode.
Setting/
Procedure
• The default setting is OFF.
ON
“OFF”
Functions
• To select whether or not to stop a print cycle when the IU reaches its service life.
Use
• Use to select not to stop the print cycle when the IU reaches its service life.
Setting/
Procedure
The default setting is Stop.
“Stop”
No Stop