K134sm7e2
7-31
7. 2. 2.16 Completely white (No image)
Check the following matters with the Pattern Print, pattern: #01_00.
If necessary use other Test Patterns.
Cause
Checking
order
Checking
Result
Treatment
Developer Press
Unit
1
Is the Developer Unit correctly pressed
to the Drum?
No
Check the Developer Press
Unit.
Driving mechanism
of Developer Unit
2
Does the Developer Roller rotate during
the print?
No
Check the driving
mechanism of Process Unit.
Developer Bias
3
Is each Electrode Plate on the right of
the Developer Unit surely contacted to
the Electrode Plate on the machine
side?
No
Try to install the Developer
Unit so that they are
contacted each other.
And supply the conductive
grease to the Electrode
Plates.
LED Head
4
Are connectors of signal cable firmly
connected to the LED Head?
No
Connect them firmly.
Turn off the machine in the middle of
printing, and then check the toner
image on the Drum.
Is there any toner image on the Drum?
No
Replace the LED Head.
Transfer/Separation
Corona
5
Is the Transfer Corona Wire broken?
Yes
Replace it.
Is the Transfer/Separation Corona Unit
correctly installed to the machine?
No
Install it correctly.
If the high voltage leaking from the
Transfer Corona?
Yes
Check the Transfer /
Separation Corona to find
the cause for leaking.
Lead Wire of
Transfer Corona
6
Is the connection of Lead Wire correct?
No
Connect it correctly.
Is the resistance of Lead Wire about 10
kilo ohms, which connects HV Power
Supply and the Transfer Corona?
No
Replace the Lead Wire.
HV Power Supply
7
Can you fix the problem if you replace
the HV Power Supply?
Yes
OK
PW13420 PCB
8
Can you fix the problem if you replace
PW13420 PCB?
Yes
OK
7. 2. 2.17 Completely black
Check the following matters with the Pattern Print, pattern: #01_00 and pattern: #04_00.
If necessary use other Test Patterns.
Cause
Checking
order
Checking
Result
Treatment
Image Corona or
HV Power Supply
PCB
1
Is the Image Corona Wire broken?
Yes
Replace it.
Is the tension of the Corona Wire
correct?
No
Replace it.
Is the Corona Wire correctly stretched
with the spring?
No
Check whether or not the
spring is transformed.
Is a proper high voltage supplied to the
Image Corona?
No
Adjust the high voltage, or
replace the HV Power
Supply PCB
Is the housing of Image Corona
insulated from the ground?
No
Replace the Zener PCB.
PW13420 PCB
2
Can you fix the problem if you replace
PW13420 PCB?
Yes
OK
Summary of Contents for 7170K
Page 1: ...KIP 7170K Service Manual Version A...
Page 46: ...K134sm2e5 2 28 7 Press GUIDES 8 Press Help 9 Press Settings SETTINGS screen appears...
Page 76: ...K134sm2e6 2 58 31 Type 4 with keypad and then click OK on the bottom 32 Click OK on the bottom...
Page 108: ...K134sm4e1 4 4 120V model 230V model 8 7 10 11 12 15 14 13 9...
Page 189: ...K134sm5e4 5 36 64 Press GUIDES 65 Press Help...
Page 384: ...K134sm5eH 5 231 3 Remove both Covers 3 5 6 pulling their sides outward 5 6...
Page 395: ...K134sm5eH 5 242 6 Remove the Blower 9 BL3 BL4 moving as the following photos 9 9...
Page 502: ...K134sm6e1 6 15...
Page 563: ...K134Ksm8e2 8 4 4 Press GUIDES 5 Press Help...
Page 564: ...K134Ksm8e2 8 5 6 Press Setting to indicate SETTINGS page...
Page 594: ...K134Ksm8e2 8 35 2 Press All Items 3 Press Export...
Page 747: ...K134Ksm8e7 8 188 8 9 2 Operation in Error Mask 1 Press Error Mask...
Page 749: ...K134Ksm8e7 8 190 8 9 3 Operation in Jam Mask 1 Press Jam Mask...
Page 750: ...K134Ksm8e7 8 191 2 Select the desired target...
Page 754: ...K134Ksm8e7 8 195 8 11 2 Changing Counter Value 1 Press Total Count 2 Press Edit...
Page 756: ...K134Ksm8e7 8 197 5 Press Edit to enable new value 6 Close the following message pressing OK...
Page 777: ...K134Ksm8e7 8 218 8 19 Communication Reset NOTE This function is not used in the market...
Page 839: ...K134sm8e8 8 280 29 Double click on the row No 15 Stitch Setting 1...
Page 863: ...K134sm9e1 Chapter 9 Appendix...
Page 864: ...KIP 7170 Overall Circuit Diagram USA 120V_KCS...