K134Ksm8e3
8-52
NOTE: All items
grayed
are not generally for field technician use
Item
No.
Setting Item
Unit
Default
Value
Setting
range
USA
EUR
/ AS
CN
CND
516 Fuser Motor Speed applied at 30mm from trailing edge
(Film)
-
0
0
0
0
0 to 80
517
to
612
Reserved
613 Judgement Value for Additional Cut Length for Non-
standard Size Prints (36”/ 34”/ 30”/ A0 / B1)
1mm
1
1
1
1
1 to 20
614 Judgement Value for Additional Cut Length for Non-
standard Size Prints (24”/ 20”/ A1)
1mm
1
1
1
1
1 to 20
615 Judgement Value for Additional Cut Length for Non-
standard Size Prints (18”/ 17”/ 15”/ A2)
1mm
1
1
1
1
1 to 20
616 Judgement Value for Additional Cut Length for Non-
standard Size Prints (12”/ 11”/ A3)
1mm
1
1
1
1
1 to 20
617 Additional Cut Length for Non-standard Size Prints
(36”/ 34”/ 30”/ A0 / B1)
1mm
0
0
0
0
0 to 35
618 Additional Cut Length for Non-standard Size Prints
(24”/ 22”/ A2)
1mm
0
0
0
0
0 to 35
619 Additional Cut Length for Non-standard Size Prints
(18”/ 17”/ 15”/ A2)
1mm
0
0
0
0
0 to 35
620 Additional Cut Length for Non-standard Size Prints
(12”/ 11”/ A3)
1mm
0
0
0
0
0 to 35
621 Toner Supply Roller Bias
Hexadecimal
d0
d0
d0
d0
0 to 3FF
622 Regulation Bias
Hexadecimal
dE
dE
dE
dE
0 to 3FF
623 Density Sensor Standard Output
0
0
0
0
0 to 614
624 Density Sensor Analog Voltage
0
0
0
0
0 to 614
625 Print - Fuser Temperature Side
(Plain) (12” / 11” / A3)
1
o
C
160
145
145
165
120 to 180
626 Print - Fuser Temperature Side
(Tracing) (12” / 11” / A3)
1
o
C
160
150
140
135
120 to 180
627 Print - Fuser Temperature Side
(Film) (12” / 11” / A3)
1
o
C
177
170
170
155
120 to 180
628 Print - Fuser Temperature Side
(Special / Plain) (12” / 11” / A3)
1
o
C
160
160
160
160
120 to 180
629 Print - Fuser Temperature Side
(Special / Tracing) (12” / 11” / A3)
1
o
C
160
160
160
160
120 to 180
630 Print - Fuser Temperature Side
(Special media / Film) (12” / 11” / A3)
1
o
C
177
170
170
170
120 to 180
631 Print - Fuser Temperature Side
(Plain) (18” / 17” / 15” / A2)
1
o
C
160
165
165
165
120 to 180
632 Print - Fuser Temperature Side
(Tracing) (18” / 17” / 15” / A2)
1
o
C
160
170
160
155
120 to 180
633 Print - Fuser Temperature Side
(Film) (18” / 17” / 15” / A2)
1
o
C
177
170
170
155
120 to 180
634 Print - Fuser Temperature Side
(Special / Plain) (18” / 17” / 15” / A2)
1
o
C
160
160
160
160
120 to 180
635 Print - Fuser Temperature Side
(Special / Tracing) (18” / 17” / 15” / A2)
1
o
C
160
160
160
160
120 to 180
636 Print - Fuser Temperature Side
(Special / Film) (18” / 17” / 15” / A2)
1
o
C
177
170
170
170
120 to 180
637 Print - Fuser Temperature Side
(Plain) (24” / 22” / A1)
1
o
C
160
165
165
165
120 to 180
638 Print - Fuser Temperature Side
(Tracing) (24” / 22” / A1)
1
o
C
160
170
160
155
120 to 180
639 Print - Fuser Temperature Side
(Film) (24” / 22” / A1)
1
o
C
177
170
170
155
120 to 180
640 Print - Fuser Temperature Side
(Special / Plain) (24” / 22” / A1)
1
o
C
160
160
160
160
120 to 180
641 Print - Fuser Temperature Side
(Special / Tracing) (24” / 22” / A1)
1
o
C
160
160
160
160
120 to 180
642 Print - Fuser Temperature Side
(Specia / Film) (24” / 22” / A1)
1
o
C
177
170
170
170
120 to 180
643 Print - Fuser Temperature Side
(Plain) (36” / 34” / 30” / A0 / B1)
1
o
C
160
165
165
165
120 to 180
644 Print - Fuser Temperature Side
(Tracing) (36” / 34” / 30” / A0 / B1)
1
o
C
160
170
160
155
120 to 180
645 Print - Fuser Temperature Side
(Film) (36” / 34” / 30” / A0 / B1)
1
o
C
177
170
170
155
120 to 180
646 Print - Fuser Temperature Side
(Special / Plain) (36” / 34” / 30” / A0 / B1)
1
o
C
160
160
160
160
120 to 180
647 Print - Fuser Temperature Side
(Special / Tracing) (36” / 34” / 30” / A0 / B1)
1
o
C
160
160
160
160
120 to 180
648 Print - Fuser Temperature Side
(Special / Film) (36” / 34” / 30” / A0 / B1)
1
o
C
177
177
177
177
120 to 180
649 Density Sensor Output Monitor
1
1
1
1
0 to 4
Summary of Contents for 7170K
Page 1: ...KIP 7170K Service Manual Version A...
Page 46: ...K134sm2e5 2 28 7 Press GUIDES 8 Press Help 9 Press Settings SETTINGS screen appears...
Page 76: ...K134sm2e6 2 58 31 Type 4 with keypad and then click OK on the bottom 32 Click OK on the bottom...
Page 108: ...K134sm4e1 4 4 120V model 230V model 8 7 10 11 12 15 14 13 9...
Page 189: ...K134sm5e4 5 36 64 Press GUIDES 65 Press Help...
Page 384: ...K134sm5eH 5 231 3 Remove both Covers 3 5 6 pulling their sides outward 5 6...
Page 395: ...K134sm5eH 5 242 6 Remove the Blower 9 BL3 BL4 moving as the following photos 9 9...
Page 502: ...K134sm6e1 6 15...
Page 563: ...K134Ksm8e2 8 4 4 Press GUIDES 5 Press Help...
Page 564: ...K134Ksm8e2 8 5 6 Press Setting to indicate SETTINGS page...
Page 594: ...K134Ksm8e2 8 35 2 Press All Items 3 Press Export...
Page 747: ...K134Ksm8e7 8 188 8 9 2 Operation in Error Mask 1 Press Error Mask...
Page 749: ...K134Ksm8e7 8 190 8 9 3 Operation in Jam Mask 1 Press Jam Mask...
Page 750: ...K134Ksm8e7 8 191 2 Select the desired target...
Page 754: ...K134Ksm8e7 8 195 8 11 2 Changing Counter Value 1 Press Total Count 2 Press Edit...
Page 756: ...K134Ksm8e7 8 197 5 Press Edit to enable new value 6 Close the following message pressing OK...
Page 777: ...K134Ksm8e7 8 218 8 19 Communication Reset NOTE This function is not used in the market...
Page 839: ...K134sm8e8 8 280 29 Double click on the row No 15 Stitch Setting 1...
Page 863: ...K134sm9e1 Chapter 9 Appendix...
Page 864: ...KIP 7170 Overall Circuit Diagram USA 120V_KCS...