K134sm8e6
8-143
8. 4. 3. 105 Print - Fuser Temperature Side (24”/22”/A1) (No.637 to 642)
It is possible to adjust the side part of Fuser Temperature in a print cycle.
You can specify the temperature for each type and size of media separately.
The Fuser Temperature becomes 1 degree higher if you increase the setting value by “+1”.
Item
No.
Setting Item
Default value
Setting
range
Step of
increment
USA
EUR/ASIA
CN
CND
637
Print - Fuser Temperature Side
(Plain) (24” / 22” / A1)
160
165
165
165
120 to
180
1
o
C
638
Print - Fuser Temperature Side
(Tracing) (24” / 22” / A1)
160
170
160
155
120 to
180
1
o
C
639
Print - Fuser Temperature Side
(Film) (24” / 22” / A1)
177
170
170
155
120 to
180
1
o
C
640
Print - Fuser Temperature Side
(Special / Plain) (24” / 22” / A1)
160
160
160
160
120 to
180
1
o
C
641
Print - Fuser Temperature Side
(Special / Tracing) (24” / 22” / A1)
160
160
160
160
120 to
180
1
o
C
642
Print - Fuser Temperature Side
(Special / Film) (24” / 22” / A1)
177
170
170
170
120 to
180
1
o
C
8. 4. 3. 106 Print - Fuser Temperature Side (36”/34”/30”/A0/B1)
(No.643 to 648)
It is possible to adjust the side part of Fuser Temperature in a print cycle.
You can specify the temperature for each type and size of media separately.
The Fuser Temperature becomes 1 degree higher if you increase the setting value by “+1”.
Item
No.
Setting Item
Default value
Setting
range
Step of
increment
USA
EUR/ASIA
CN
CND
643
Print - Fuser Temperature Side
(Plain) (36” / 34” / 30” / A0 / B1)
160
165
165
165
120 to 180
1
o
C
644
Print - Fuser Temperature Side
(Tracing) (36” / 34” / 30” / A0 / B1)
160
170
160
155
120 to 180
1
o
C
645
Print - Fuser Temperature Side
(Film) (36” / 34” / 30” / A0 / B1)
177
170
170
155
120 to 180
1
o
C
646
Print - Fuser Temperature Side
(Special / Plain) (36” / 34” / 30” /
A0 / B1)
160
160
160
160
120 to 180
1
o
C
647
Print - Fuser Temperature Side
(Special / Tracing) (36” / 34” / 30” /
A0 / B1)
160
160
160
160
120 to 180
1
o
C
648
Print - Fuser Temperature Side
(Special / Film) (36” / 34” / 30” / A0
/ B1)
177
177
177
177
120 to 180
1
o
C
Reference
The center part of Fuser Temperature will be controlled by Print - Fuser Temperature Center
(No. 039 to 044) separately.
Refer to [8. 4. 3.17 Print - Fuser Temperature Center (No.039 to 044)] for further
information.
Reference
The center part of Fuser Temperature will be controlled by Print - Fuser Temperature Center
(No. 039 to 044) separately.
Refer to [8. 4. 3.17 Print - Fuser Temperature Center (No.039 to 044)] for further
information.
Summary of Contents for 7170K
Page 1: ...KIP 7170K Service Manual Version A...
Page 46: ...K134sm2e5 2 28 7 Press GUIDES 8 Press Help 9 Press Settings SETTINGS screen appears...
Page 76: ...K134sm2e6 2 58 31 Type 4 with keypad and then click OK on the bottom 32 Click OK on the bottom...
Page 108: ...K134sm4e1 4 4 120V model 230V model 8 7 10 11 12 15 14 13 9...
Page 189: ...K134sm5e4 5 36 64 Press GUIDES 65 Press Help...
Page 384: ...K134sm5eH 5 231 3 Remove both Covers 3 5 6 pulling their sides outward 5 6...
Page 395: ...K134sm5eH 5 242 6 Remove the Blower 9 BL3 BL4 moving as the following photos 9 9...
Page 502: ...K134sm6e1 6 15...
Page 563: ...K134Ksm8e2 8 4 4 Press GUIDES 5 Press Help...
Page 564: ...K134Ksm8e2 8 5 6 Press Setting to indicate SETTINGS page...
Page 594: ...K134Ksm8e2 8 35 2 Press All Items 3 Press Export...
Page 747: ...K134Ksm8e7 8 188 8 9 2 Operation in Error Mask 1 Press Error Mask...
Page 749: ...K134Ksm8e7 8 190 8 9 3 Operation in Jam Mask 1 Press Jam Mask...
Page 750: ...K134Ksm8e7 8 191 2 Select the desired target...
Page 754: ...K134Ksm8e7 8 195 8 11 2 Changing Counter Value 1 Press Total Count 2 Press Edit...
Page 756: ...K134Ksm8e7 8 197 5 Press Edit to enable new value 6 Close the following message pressing OK...
Page 777: ...K134Ksm8e7 8 218 8 19 Communication Reset NOTE This function is not used in the market...
Page 839: ...K134sm8e8 8 280 29 Double click on the row No 15 Stitch Setting 1...
Page 863: ...K134sm9e1 Chapter 9 Appendix...
Page 864: ...KIP 7170 Overall Circuit Diagram USA 120V_KCS...