K134sm8e6
8-146
8. 4. 3. 111 Target Density (No.653)
It is possible to change Target Density that should be achieved and maintained for consistent print
density.
If the current density does not meet Target Density, Regulation (Developer) Bias will be
automatically adjusted based on the current Adjustment Level.
•
If the current Density Value is judged “not enough” (lighter than required), the next level will be
applied.
•
If the current Density Value is judged “adequate”, the current level remains.
•
There is possibility for the Density Value to be judged “too much enough” (darker than
required), then the previous level will be applied.
If you increase the setting value by “+1”, Target Density will rise and thus Auto Adjustment Level
would be switched to the next level earlier.
Default Value
Setting Range
Step of increment
135
110 to 150
1
8. 4. 3. 112 Regulation Bias Maximum (No.654)
It is possible to change the maximum of Regulation Bias.
When the total value amount of Regulation Bias (No.622) and Total Increment of Regulation Bias
Adjustment (No.641) reaches to the value of this setting, Regulation Bias cannot raise any more.
If you increase the setting value by “+1”, the maximum of Regulation Bias increases.
Default Value
Setting Range
Step of increment
293
0 to 1023
1
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
NOTE
This setting has been factory-adjusted. Keep the value unchanged.
Summary of Contents for 7170K
Page 1: ...KIP 7170K Service Manual Version A...
Page 46: ...K134sm2e5 2 28 7 Press GUIDES 8 Press Help 9 Press Settings SETTINGS screen appears...
Page 76: ...K134sm2e6 2 58 31 Type 4 with keypad and then click OK on the bottom 32 Click OK on the bottom...
Page 108: ...K134sm4e1 4 4 120V model 230V model 8 7 10 11 12 15 14 13 9...
Page 189: ...K134sm5e4 5 36 64 Press GUIDES 65 Press Help...
Page 384: ...K134sm5eH 5 231 3 Remove both Covers 3 5 6 pulling their sides outward 5 6...
Page 395: ...K134sm5eH 5 242 6 Remove the Blower 9 BL3 BL4 moving as the following photos 9 9...
Page 502: ...K134sm6e1 6 15...
Page 563: ...K134Ksm8e2 8 4 4 Press GUIDES 5 Press Help...
Page 564: ...K134Ksm8e2 8 5 6 Press Setting to indicate SETTINGS page...
Page 594: ...K134Ksm8e2 8 35 2 Press All Items 3 Press Export...
Page 747: ...K134Ksm8e7 8 188 8 9 2 Operation in Error Mask 1 Press Error Mask...
Page 749: ...K134Ksm8e7 8 190 8 9 3 Operation in Jam Mask 1 Press Jam Mask...
Page 750: ...K134Ksm8e7 8 191 2 Select the desired target...
Page 754: ...K134Ksm8e7 8 195 8 11 2 Changing Counter Value 1 Press Total Count 2 Press Edit...
Page 756: ...K134Ksm8e7 8 197 5 Press Edit to enable new value 6 Close the following message pressing OK...
Page 777: ...K134Ksm8e7 8 218 8 19 Communication Reset NOTE This function is not used in the market...
Page 839: ...K134sm8e8 8 280 29 Double click on the row No 15 Stitch Setting 1...
Page 863: ...K134sm9e1 Chapter 9 Appendix...
Page 864: ...KIP 7170 Overall Circuit Diagram USA 120V_KCS...