![KIP 7170K Service Manual Download Page 710](http://html1.mh-extra.com/html/kip/7170k/7170k_service-manual_1971664710.webp)
K134sm8e6
8-151
8. 4. 3. 121 Fuser Motor Speed applied at 100mm from trailing edge
(36” / 34” / 30” / A0 / B1 width) (No.743 to 745)
It is possible to adjust the speed of Fuser Motor driving on 100mm end of a print in 36” / 34” / 30” /
A0 / B1 width.
This setting may be a solution for image void on the trailing center.
If you increase the setting value by “+1”, speed of Fuser Motor driving becomes 0.04mm/s slower
than the applied speed at that point.
Item
No.
Setting Item
Default value
Setting
range
Step of
increment
USA
EUR/AS
CN
CND
743
Fuser Motor Speed applied at 100mm from trailing
edge (36” / 34” / 30” / A0 / B1 width) (Plain)
0
1
1
1
0 to 80
0.04mm/s
744
Fuser Motor Speed applied at 100mm from trailing
edge (36” / 34” / 30” / A0 / B1 width) (Tracing)
0
15
15
15
0 to 80
0.04mm/s
745
Fuser Motor Speed applied at 100mm from trailing
edge (36” / 34” / 30” / A0 / B1 width) (Film)
0
0
0
0
0 to 80
0.04mm/s
8. 4. 3. 122 Roll 2 Forward Standby ON/OFF (No.746)
The default Standby Position for the leading edge of Roll 2 is located directly below the set sensor
(PH9). This setting will feed the leading edge to Forward Standby Position (approximately 252mm
forward from the default Standby Position).
Default value
Setting value
Contents
0
0
Roll 2 Leading Edge stays at the set sensor
1
Roll 2 Leading Edge goes Forward Standby Position
8. 4. 3. 123 Roll 2 Forward Standby Position Adjustment (No.747)
This setting can adjust Roll 2 Forward Standby Position (approximately 202 to 252mm forward
from the default Roll 2 Standby Position) with Roll 2 Forward Standby on. When the setting value
increases by 1, Roll 2 Forward Standby Position will shift backward to the default Standby Position
in 1mm. (“0” for 252mm forward, “50” for 202mm forward)
Default Value
Setting Range
Step of increment
0
0 to 50
1mm
8. 4. 3. 124 Roll 2 Rewind Timer (No. 748)
This setting can work as a timer to rewind Roll 2 media from Forward Standby Position to the
default Standby Position with Roll 2 Forward Standby on. When the setting value decreases by 1,
the interval of rewinding Roll 2 media to the default Standby Position becomes 1 minute shorter.
When the setting value is "0", the roll media is not rewound.
Default Value
Setting Range
Step of increment
15
0 to 15
1 min
Summary of Contents for 7170K
Page 1: ...KIP 7170K Service Manual Version A...
Page 46: ...K134sm2e5 2 28 7 Press GUIDES 8 Press Help 9 Press Settings SETTINGS screen appears...
Page 76: ...K134sm2e6 2 58 31 Type 4 with keypad and then click OK on the bottom 32 Click OK on the bottom...
Page 108: ...K134sm4e1 4 4 120V model 230V model 8 7 10 11 12 15 14 13 9...
Page 189: ...K134sm5e4 5 36 64 Press GUIDES 65 Press Help...
Page 384: ...K134sm5eH 5 231 3 Remove both Covers 3 5 6 pulling their sides outward 5 6...
Page 395: ...K134sm5eH 5 242 6 Remove the Blower 9 BL3 BL4 moving as the following photos 9 9...
Page 502: ...K134sm6e1 6 15...
Page 563: ...K134Ksm8e2 8 4 4 Press GUIDES 5 Press Help...
Page 564: ...K134Ksm8e2 8 5 6 Press Setting to indicate SETTINGS page...
Page 594: ...K134Ksm8e2 8 35 2 Press All Items 3 Press Export...
Page 747: ...K134Ksm8e7 8 188 8 9 2 Operation in Error Mask 1 Press Error Mask...
Page 749: ...K134Ksm8e7 8 190 8 9 3 Operation in Jam Mask 1 Press Jam Mask...
Page 750: ...K134Ksm8e7 8 191 2 Select the desired target...
Page 754: ...K134Ksm8e7 8 195 8 11 2 Changing Counter Value 1 Press Total Count 2 Press Edit...
Page 756: ...K134Ksm8e7 8 197 5 Press Edit to enable new value 6 Close the following message pressing OK...
Page 777: ...K134Ksm8e7 8 218 8 19 Communication Reset NOTE This function is not used in the market...
Page 839: ...K134sm8e8 8 280 29 Double click on the row No 15 Stitch Setting 1...
Page 863: ...K134sm9e1 Chapter 9 Appendix...
Page 864: ...KIP 7170 Overall Circuit Diagram USA 120V_KCS...