8. 4. 3. 156 Detection Time of Fuser Temperature Heat-up Error
(No. 819 to 821)
It is possible to adjust the detection time of fuser temperature heat-up error.
Item
No.
Setting Item
Default value
Setting range Step of
increment
USA
EUR/AS
CN
CND
819 Detection Time of Fuser Temperature
Heat-up Error 1
120
120
120
120
120 to 240
1 second
820 Detection Time of Fuser Temperature
Heat-up Error 2
150
150
150
150
150 to 240
1 second
821 Detection Time of Fuser Temperature
Heat-up Error 3
330
330
330
330
330 to 480
1 second
Detection Time of Fuser Temperature Heat-up Error 1 (No. 819)
If the fuser temperature does not rise up from 0 to 50 degrees C. within 120 seconds "Fuser
Temperature Rising Error (E-000)" occurs.
It is possible to adjust the detection time for this error. ( part in the following figure)
When the setting value is increased by "1", the detection time for the error becomes 1 second
longer.
Detection Time of Fuser Temperature Heat-up Error 2 (No. 820)
If the fuser temperature does not rise up from 50 to 100 degrees C. within 150 seconds, "Fuser
Low Temperature Error (E-002)" occurs.
It is possible to adjust the detection time for this error. ( part in the following figure)
When the setting value is increased by "1", the detection time for the error becomes 1 second
longer.
Detection Time of Fuser Temperature Heat-up Error 3 (No. 821)
If the fuser temperature does not rise up from 100 degrees C. to the fuser temperature at the ready
within 330 seconds, "Fuser Low Temperature Error (E-002)" occurs.
It is possible to adjust the detection time for this error. ( part in the following figure)
When the setting value is increased by "1", the detection time for the error becomes 1 second
longer.
NOTE
Do not change the setting value!
Changing these setting value is not required in the field under the normal operation.
A
B
C
Summary of Contents for 7170K
Page 1: ...KIP 7170K Service Manual Version A...
Page 46: ...K134sm2e5 2 28 7 Press GUIDES 8 Press Help 9 Press Settings SETTINGS screen appears...
Page 76: ...K134sm2e6 2 58 31 Type 4 with keypad and then click OK on the bottom 32 Click OK on the bottom...
Page 108: ...K134sm4e1 4 4 120V model 230V model 8 7 10 11 12 15 14 13 9...
Page 189: ...K134sm5e4 5 36 64 Press GUIDES 65 Press Help...
Page 384: ...K134sm5eH 5 231 3 Remove both Covers 3 5 6 pulling their sides outward 5 6...
Page 395: ...K134sm5eH 5 242 6 Remove the Blower 9 BL3 BL4 moving as the following photos 9 9...
Page 502: ...K134sm6e1 6 15...
Page 563: ...K134Ksm8e2 8 4 4 Press GUIDES 5 Press Help...
Page 564: ...K134Ksm8e2 8 5 6 Press Setting to indicate SETTINGS page...
Page 594: ...K134Ksm8e2 8 35 2 Press All Items 3 Press Export...
Page 747: ...K134Ksm8e7 8 188 8 9 2 Operation in Error Mask 1 Press Error Mask...
Page 749: ...K134Ksm8e7 8 190 8 9 3 Operation in Jam Mask 1 Press Jam Mask...
Page 750: ...K134Ksm8e7 8 191 2 Select the desired target...
Page 754: ...K134Ksm8e7 8 195 8 11 2 Changing Counter Value 1 Press Total Count 2 Press Edit...
Page 756: ...K134Ksm8e7 8 197 5 Press Edit to enable new value 6 Close the following message pressing OK...
Page 777: ...K134Ksm8e7 8 218 8 19 Communication Reset NOTE This function is not used in the market...
Page 839: ...K134sm8e8 8 280 29 Double click on the row No 15 Stitch Setting 1...
Page 863: ...K134sm9e1 Chapter 9 Appendix...
Page 864: ...KIP 7170 Overall Circuit Diagram USA 120V_KCS...