88
DOWN SOUND
There is an audible sound available to alarm when the model is descending. Initially it is set to “INH”.
Descent speed can be set within positive or negative 3.0m/s (m/f) to 0.1m/s (m/f).
Setup Example
[To set an integrated vario]: To know if the aircraft is climbing, set the "UP SOUND" to be active at say 0.5m/sec
(minimum value 0.1m/sec) - now if your aircraft climbs at greater than 0.5m/sec you will receive an audible tone.
[To set a net vario]: Set a value more positive than the still air sink rate of your aircraft as the “UP SOUND” to know
if the surrounding air is rising. For example, if the aircraft still air sink rate is -1.0m/sec, set an alarm value of
-0.7m/sec. With this setting, you get informed when the surrounding air is rising at more than 0.3m/sec. To get a
net sink rate, set the alarm to a value more negative than the still air sink rate of your aircraft. In this example, set
the “DOWN SOUND” to a value of -1.3m/sec. Note: if the up sound and down sound are very close in values, you
may get false alarms caused by small aircraft movements.
Switch Select (SW SEL)
It is possible to set the Alert to be active by switches or stick position, or a combination of those devices by using
“SW SEL”. Initially it is always turned on.
▋
▋
For▋Motive▋Power▋Battery▋(FLIGHT▋PACK)
Motive Power Battery Alarm (VOLT-ALARM)
It is possible to set an alert for low Motive Power
Battery voltage. Initially it is set as Inhibited. Set
the alert voltage as desired. The Voltage can be set
between 0.1V 〜 655.3V in 0.1V increments.
Nominal Capacity Value (CAPACITY)
It is possible to set a Nominal Capacity Value to
match your Motive Power battery capacity. The remaining battery capacity value is displayed by deducting the
consumed capacity value. It can be set between 0mAh 〜 30,000mAh, in 10mAh increments.
Battery Capacity Alarm (CAPA-ALARM)
It is possible to set a capacity remaining alert based on the Nominal Capacity value of your battery. Initially it is
set as Inhibited. To activate, set a percentage between 0% to 100%. The alarm will sound when this calculated
percent capacity remaining reaches this figure.
▋
▋
Current▋and▋Wattage▋indication▋can▋be▋displayed▋on▋the▋screen.
F-PACK AMP ���� CURRENT (Amperage)
F-PACK WATT ���� POWER(Wattage)
Under the Flight pack telemetry use on Sub INFO screen, select either “F- PACK AMP ” or “F- PACK WATT” by
pressing the dial there will be a “ POP UP” indication on the screen, Each display shows present (NOW) and Peak
value(PEAK)on Amperage and Wattage.
Refer to the Page 24 "Sub information screen"
ダイヤル
TIPS
調整ポイント表示
ポイント接続を曲線に変更
スティック入力位置と出力位置の数値表示
現在の
フライトモード位置
各調整ポイントの
入力位置と出力位置
ポイントの
追加と削除
注意:
グラフはホバリン
グスロットルやス
ロットルトリムで
変化する場合もあ
ります。
カーブをコピー
By using the Information screen, it is possible to display your desired Telemetry information on the first page, together
with the Timer and Flight Mode selection on a screen that customers can customize so that it is easy to check.
Initially it is set as Inhibited. Select the telemetry information to be displayed, and allocate it to a position on the screen.
▋
▋
Caution▋Note
The Telemetry sensor data is ment as an indication only, and therefore we cannot guarantee the accuracy of any
recordings obtained.
System▋List▋
Sub INFO display
F Pack screen
Sub Selection Screen
SUB INFO SCREEN
Sub INFO display
F Pack screen
Sub Selection Screen
SUB INFO SCREEN
Summary of Contents for XG11
Page 1: ......
Page 2: ......
Page 103: ...101...
Page 109: ...107 Data Sheet...
Page 115: ...113 Data Sheet...
Page 123: ......
Page 124: ......