Section 2
iVIZION® Series Next-Generation Banknote Acceptor Unit
Installation
Cable Interconnection
Figure 2-4 illustrates the Cable Harness intercon-
nection requirements between the iVIZION
®
and a
Host Machine.
DIP Switch Configurations
This portion provides the denomination DIP Switch
Block Settings for the iVIZION
®
Unit.
P
RIMARY
LED I
NDICATIONS
The iVIZION
®
Unit’s pair of Color LEDs illumi-
nate when various operating and error conditions
occur.
Table 2-1
Denomination INHIBIT DIP Switch
Settings
Validation CPU Board SW1
Switch
No.
Switch ON
Switch OFF
1
VEND 1 INHIBIT
VEND 1 ACCEPT
2
VEND 2 INHIBIT
VEND 2 ACCEPT
3
VEND 3 INHIBIT
VEND 3 ACCEPT
4
VEND 4 INHIBIT
VEND 4 ACCEPT
5
VEND 5 INHIBIT
VEND 5 ACCEPT
6
VEND 6 INHIBIT
VEND 6 ACCEPT
7
VEND 7 INHIBIT
VEND 7 ACCEPT
8
N/A
*
*. Not Applicable (N/A). Never Switched to ON.
OFF (Fixed)
NOTE: When installing the iVIZION
®
LD
Version Unit into a related Machine, refer to
the iVIZION Optional LD Version Unit
Installation detailed information on page 2-9.
a
b
c
d
a) iVIZION
®
Unit
b) Interface Connector (iVIZION)
c) Harness
d) Host Machine (e.g., Game Machine, Kiosk, etc.)
Figure 2-4
Cable Interconnection
SW1
Table 2-2
JCM Private Line DIP Switch Setting
Validation CPU Board JP1
Switch
No.
Non-Marked (O)
Marked (C)
1
RS-485 Resistance
Terminated
RS-485 Resistance
Un-Terminated
Table 2-3
Software DIP Switch Settings
Controller CPU Board SW1
Switch
No.
Switch ON
Switch OFF
1
N/A
*
*. Not Applicable (N/A). Never Switched to ON.
OFF (Fixed)
2
N/A*
OFF (Fixed)
3
N/A*
OFF (Fixed)
4
N/A*
OFF (Fixed)
Table 2-4
Serial Communications DIP Switch
Settings
Controller CPU Board JP2 & JP3
Switch No.
Non-Marked (R)
Marked (P)
JP2
RS232C
Photo-Coupler
Isolation (Standard)
JP3
RS232C
Photo-Coupler
Isolation (Standard)
Table 2-5
LED Error Pattern Indications
No.
Condition
LED Indications
Power LED
*
*. The Power LED lights Green when Power is supplied to the Unit.
Status LED
1
OFF
Extinguished
(OUT)
Extinguished
(OUT)
2
Initializing
Lit Green
Blue Flashes
3
Stand-by
Lit Green
Extinguished
(OUT)
4
Reject
Lit Green
Green Flashes
5
Banknote Jam
Lit Green
Yellow Flashes
6
Abnormal
Error
Lit Green
Red Flashes
7
Downloading
Lit Green
Lit Red
Lit Green
8
Performance Test
(Stand-by)
Lit Green
Lit Blue
JP1
O
↔
C
Mark
SW1
JP2
JP3
R
↔
P
R
↔
P
Mark
NOTE: When changing the type of iVIZION
Serial Communications, Switches JP2 and
JP3 located on the Controller CPU Board
must be set to identical switch positions.