Section 6
iVIZION® SeriesNext-Generation Banknote Acceptor Unit
Calibration and Testing
9. When the “
JCM Downloader Suite…
” Screen re-
appears, Mouse-click on the center “
Download
”
Screen Button (See Figure 6-28 a) to begin the
Software download into the iVIZION
®
Unit. The
Download
Screen will display a Progress Baro-
graph during the download operation (See Figure
Blue
Text Line
below the Down-
load Screen Button will display the download
Percentage as “
Downloading : XX%
”
(See Figure 6-28 c). The Status LED will alter-
nately light
Green
and
Red
.
10. When the download is complete, the “
Download
Success. Reset Done. Waiting for USB Cable
Disconnection
.
”
Blue
Text Line will appear
(See Figure 6-29 a).
11. Confirm that the Host’s Checksum and the
Device Checksums identically match each other
(See Figure 6-29 b).
This completes the iVIZION Software Download-
ing Procedures.
Calibration
This section provides instructions for performing a
calibration of the Acceptor Unit Sensors and the
Transport Unit Sensors within the iVIZION
®
Device.
When to Calibrate
Calibration should be performed when one of the
following four (4) conditions occur:
1. When removing one of the Circuit Boards.
2. When replacing one of the Circuit Boards.
3. When dirt adheres to the Sensors (See “Sensor
Cleaning Procedure” on page 2-9 of this
Section).
4. When the Banknote Acceptance Rate becomes
drastically degraded.
C
ALIBRATION
O
RDER
Table 6-1 lists the Calibration Order related to each
iVIZION
®
Sensor’s Screen indication.
Calibration Tool Requirements
Figure 6-30 illustrates and list identifies the cali-
bration Tools and equipment interconnects neces-
sary to install an iVIZION
®
Unit away from its
Host Machine.
Figure 6-27
iVIZION Software Program Selection
a
b
Figure 6-28
Download Progress Screen 2
a
b
c
Figure 6-29
Download Completed Screen 2
a
b =
Table 6-1
iVIZION Sensor Calibration Order
Step
Screen Indication
Related Sensor
Calibration #1
Box RUNNING
Cash Box Sensor
Nearly Full RUNNING
Nearly Full Sensor
Feed-Out RUNNING
Feed-Out Sensor
Calibration #2
Home Position
RUNNING
Home Position Sensor
Feed-In
RUNNING
Feed-In Sensor
Entrance RUNNING
Entrance Sensor
Exit RUNNING
Exit Sensor
Calibration #3
UV RUNNING
UV Sensor (Upper)
UV RUNNING
UV Sensor (Lower)
Calibration #4
CIS RUNNING
CIS transmissive Sensor
CIS Sensor (Lower)
CIS Sensor (Upper)
NOTE: When the “USB “A” Terminal”
connects to the USB Hub, the iVIZION
may not be operating. Ensure that the
“USB “A” Terminal” is properly connected
directly to the USB Port of the PC.