Calibration and Testing
6. Set the External Switch Box Switch to the posi-
tion away from the Status LED on the Box.
7. Turn
the
iVIZION
®
Power Switch to
ON
. The
iVIZION
®
Status LEDs will indicate Stand-by
Mode when the Status LED on the iVIZION
®
Lights a steady
Blue
Color, and the Status LED
on the External Switch blinks at a
Red
Color rate.
8. Turn the External Switch Box Switch toward the
iVIZION
®
status LED on the Box when the
iVIZION
®
Power Switch is turned to
ON
. The
desired Test selected by DIP Switch Positions
will then begin (Refer to “Performance Test Pro-
cedures” on page 6-12 of this Section for each
test and its resulting Test indication).
9. Return the External Switch Box Switch to the
position away from the iVIZION
®
Status LED on
the Box again, and the current Test being run will
end. If other Switch Box Tests are necessary,
restart from Step 1 at the beginning of this pro-
cedure.
iVIZION Utility Tools
This portion provides information regarding each
iVIZION
®
Service Mode setting procedure.
The following two (2) Tool setting types exist
when using the iVIZION Utility Tools:
•
CIS Image Views
•
ICB Function Settings.
ICB/Image Setting Tool Requirements
The Tools listed in Figure 6-68 are required to set
or change each
iVIZION
®
ICB Setting.
ICB/Image Setting Change Preparation
Perform the following steps to set or reset the ICB
Functions.
1. Turn the iVIZION
®
Unit’s Power Switch to
ON
.
2. Launch the “
JCM Tool Suite Standard Edition
”
Application. The Figure 6-69 Screen will appear
when the application becomes activate.
3. Mouse-click on, and hold-down on the “
Service
Mode
” selection Pull-down Menu (See Figure 6-
69 a), and Slide-down select “
Utility
” from the
Pull-Down Menu Sections (See Figure 6-69 b).
The “
iVIZION Utility Tool Version X.XX for
Suite Edition
” Application Menu selection
Screen shown in Figure 6-70 will automati-
cally appear.
CIS Image Tool
The CIS Image Tool provides graphic views of the
scanned Banknote images directly. This feature is
available to confirm the last stacked Banknote
denomination by presenting its scanned front and
back images.
1. Mouse-click on the large “
1) CIS IMAGE
” Screen
Button located on the “
iVIZION Utility Tool
”
2. Confirm that the “
CIS Image
” Screen shown in
Figure 6-71 appears.
3. Mouse-click on the “
Read
” Screen Button
(See Figure 6-72 a) to see an image of the last
scanned Banknote’s upper and lower surface
images on the Screen (See Figure 6-72 b & c).
4. Mouse-click on the “
File Save
” Screen Button
(See Figure 6-71 b) if necessary to save the data.
5. Mouse-click on the “
File Read
” Screen Button
(See Figure 6-71 c) to retrieve the saved file data.
Figure 6-68
ICB Setting Tool Requirements
a) iVIZION Device
b) Power Supply
c) PC (OS: Windows XP/iVIZION USB Driver
Installed)
d) USB Cable
d
1
) USB “A” Terminal Plug
d
2
) USB “Mini-B” Terminal Plug
e) Application Software*
(JCM Tool Suite Standard Edition).
*. Containing USB Downloader, Sensor Calibration, Performance
Test programs and Utility.
a
b
d
d
1
d
2
e
c
NOTE: The ICB Function Status is initially
Factory Set to “INHIBIT” as a standard
function. Therefore, the iVIZION Unit’s ICB
must be first initialized using the USB Tool
Suite Utility Options. Refer to the JCM ICB
Installation Guide for exact programming
descriptions and operational details.
Figure 6-69
JCM Tool Suite Standard Edition
a
a
b
KF srl | www.keyfuture.com | Phone +39 059313920