P/N 960-100929R_Rev. 3 {EDP #148849}
© 2012, Japan CashMachine Co., Limited
4 - 9
Disassembly/Reassembly
iVIZION® Series Next-Generation Banknote Acceptor Unit
Section 4
4. Remove the four (4) CIS Sensor Mounting
Screws (See Figure 4-32 a
1
through a
4
) and
remove the CIS Sensor (See Figure 4-32 b) from
the Upper Validation Section.
5. Remove the two (2) mounting Screws (See Figure
4-32 c
1
& c
2
) retaining the Transmissive Light
Sensor in place (See Figure 4-32 d), and remove
it from the Upper Validation Section.
6. Remove the two (2) mounting Screws (See Figure
1
& e
2
) retaining the Upper UV Sensor in
place (See Figure 4-32 f), and drop it down and
off the Upper Validation Section.
CIS/CIS FPC/Lower UV Sensor &
Lower UV FFC Removal
To remove the CIS, the CIS FPC, the Lower UV
Sensor and the Lower UV FFC proceed as follows:
1. Remove three (3) BG 85A Head Mounting
Screws (See Figure 4-33 a
1,
a
2
& a
3
) and release
the four (4) Clip-tab Stops (See Figure 4-33 b
1
through b
4
) on the
iVIZION
®
BG 85A Head.
2. Remove
the
iVIZION
®
BG 85A Head
(See Figure 4-33 c) up and off of the Validation
Unit.
3. Remove two (2) mounting screws (See Figure 4-
34 a
1
& a
2
) retaining the Lower Validation Sec-
tion in place (See Figure 4-34 b) and remove it up
and off the Validation Unit.
NOTE: When reassembling the Unit,
ensure that the UV Sensors are correctly
re- positioned when set in place (See
“Reassembly Cautions” on page 4-10 of
this Section).
NOTE: If foreign objects are observed
adhering to the Sensor’s surface, blow it
clean by using a Compressing Air spray.
Figure 4-32
CIS, Transmissive Light & Upper UV
Sensor Removal
a
4
f
d
b
a
2
a
1
a
3
c
1
c
2
e
2
e
2
Figure 4-33
iVIZION BG 85A HEAD Removal
a
1
a
2
a
3
b
1
b
2
b
3
b
4
c
Figure 4-34
Lower Validation Part Removal
a
1
a
2
b