background image

D3740-US  REV B 

June 23, 2009 

 

 

SW4600EID 

Operators Manual 

 

 

 
 
 
 

 

Ft. Atkinson, Wisconsin  USA 

 

Helden-Beringe, The Netherlands 

www.digi-star.com

 

HELLO 

Summary of Contents for SW4600EID

Page 1: ...D3740 US REV B June 23 2009 SW4600EID Operators Manual Ft Atkinson Wisconsin USA Helden Beringe The Netherlands www digi star com HELLO...

Page 2: ...SETUP AND CALIBRATION 16 CHANGING OPTIONS 17 SETTING OPTIONS 18 MENU 1 18 MENU 2 23 MENU 3 25 MENU 4 25 CALIBRATION 26 STOCKWEIGH LINK PC SOFTWARE 27 GETTING STARTED 27 READ SOFTWARE LICENSE AGREEMEN...

Page 3: ...Operators Manual D3740 3 SCOREBOARD METHODS 39 WEIGHING ERRORS 40 OVRCAP 40 RANGE 40 RANGE 40 SOFTWARE LICENSE AGREEMENT 41 TROUBLESHOOTING 47 INSTALLATION 48 INDICATOR MOUNTING 48 CABLE CONNECTION 48...

Page 4: ...740 CHARGING BATTERY OR WELDING Figure 1 Important Precaution Important Disconnect all indicator leads before charging battery or welding equipment Damage may occur to indicator and load cells Disconn...

Page 5: ...ing and alarm sounds when weight is within preset limit 4 Press to break indicator lock on weight and reweigh Press and hold then press to enter short form calibration See page 26 5 Press in manual mo...

Page 6: ...to input letters 14 Press to undo data field or get out of long form set up 15 Keypad Press to input numbers 16 performs task displayed by select 17 toggle to determine which operation the function k...

Page 7: ...th computer and other digital input output devices such as a printer Remote EID reader port Serial Number Plate Serial Number of your Indicator Allflex EID Stick Reader Electronic ID Visual ID Optiona...

Page 8: ...ulates using difference in current weight and last weight in memory for that animal divides sum by number of days since last saved weight equals Average Daily Weight Gain Example Current weight Last s...

Page 9: ...s flashes then 0 is displayed GROUP Assigned group number alpha numeric title for group of animals to be weighed PIN Assigned premise number may be government issued unique number given to farm AV Ave...

Page 10: ...see page 23 ID numbers will need to be entered at start up of indicator 1 Press twice to accept current numbers or enter group number with keypad press Repeat for premise number Digi star Animal eid I...

Page 11: ...flash in upper display 3 Enter number of desired data field press to save can also press or to scroll through list then press to save Note For a list of existing Quick Data Fields press until you are...

Page 12: ...1 Press and hold zero balances scale Animal on platform 1 Indicator Locks On animal s weight L appears in upper left of display Display alternates between no eid and weight 2 If EID Stick Reader is no...

Page 13: ...cator turns from red to green momentarily 2 Tag may be read any time Last four digits of tag displayed flanked by before data stored 3 Release animal Weight and EID data stored 1 Visual ID VID EID Sti...

Page 14: ...sults in multiple beeping Data stored manually for animal will not be stored when animal steps off scale Automatic mode will resume for next animal Stick Reader can read data from other devices such a...

Page 15: ...F and LO BAT shows on display After 2 minutes indicator shuts off Note Disconnect indicator from battery while recharging DAMAGE CAN OCCUR to indicator and stick reader 1 Press while on the weigh or s...

Page 16: ...ilograms 6600KG StockWeigh 6600 kilograms 10K KG StockWeigh 10000 kilograms 14K KG StockWeigh 14000 kilograms Custom Press indicator SETUP displays and then 6 digit number with right digit flashing To...

Page 17: ...ain until desired menu shows 3 Press to see first option 1 When option displayed press 2 Press records changes and next option 3 Press to exit 1 2 1 2 3 Menu 1 Menu 1 Menu 1 Menu 1 Press select for me...

Page 18: ...3 4 Update display times per seconds Motion Arrow Motion Motion Motion Motion 103 ON OFF Arrow flashes for unstable weight Zero Tracking ZTRACK ZTRACK ZTRACK ZTRACK 104 ON OFF Zero track adjusts to z...

Page 19: ...EID data Indicator does not store data to memory Sends data to computer port only when APRINT set to ON Set PRTFMT to select desired print format Manual Print MANPRT MANPRT MANPRT MANPRT Indicator doe...

Page 20: ...l print even if EID not provided Automatic Weight AUTOWT AUTOWT AUTOWT AUTOWT Indicator accepts EID data Message will not alert operator if EID data missing Indicator does not store data in memory Sen...

Page 21: ...at Data stored in EID data format If ESTORE OFF data not stored into indicator memory Automatic EID AUTEID Indicator accepts EID data Message alerts operator if EID data missing Sends EID time date we...

Page 22: ...ID data format If ESTORE OFF data not stored into indicator memory Automatic Check AUTCHK AUTCHK AUTCHK AUTCHK Indicator accepts EID data Message alerts operator if EID data missing Press prints and s...

Page 23: ...ta per LSTORE and ESTORE settings after EID tag read Weight on scale tag read scale operates normally EIDAUT has no effect Off in most weighing applications Scroll SCROLL SCROLL SCROLL SCROLL 118 0 1...

Page 24: ...output to one line Scoreboard Mode SCOREM SCOREM SCOREM SCOREM 213 0 10 13 21 26 Methods to output display data to scoreboard via com port See page 39 Auto Print APRINT APRINT APRINT APRINT 214 ON OFF...

Page 25: ...DJUST WMA 1 1 305 10 Increase number to smooth weighing WM1 ADJUST 2 WMA 1 WMA 1 WMA 1 WMA 1 2 2 2 2 306 0 1 2 3 4 5 6 7 8 9 0 OFF Use values less than WMA 1 1 for quick weight response WM1 ADJUST 3 W...

Page 26: ...eight below SETPNT to change 12VDC alarm SETDEL 425 0 Time before 12 VDC alarm output changes SETOUT 426 OVER UNDER 12 VDC alarm 12 VDC when over or under setpnt SETCTR 427 0 1 2 3 4 5 6 7 8 9 Use key...

Page 27: ...tes A USB to Serial Port Adapter used if PC does not have a free serial port Certain programs interfere with operation of serial port StockWeigh Link Programs include Palm Desktop and some auto ID sof...

Page 28: ...find the indicator Receiving Data Click the Retrieve Data button to retrieve all of the information on the indicator After retrieving the data it will ask if you want to clear the indicator Note If yo...

Page 29: ...ext to the the bottom row and then type in the name of the File you want to add then click Save To Delete a Quick Note File Click on the name of the File you want to delete and click Delete To Receive...

Page 30: ...o edit and click Select To Add a Quick Note Click in the box next to the and type in note Then click Save Note Each Quick Note can only be 26 characters long To Delete a Quick Note Click on the note y...

Page 31: ...ow Adjust what columns of data are displayed by checking and unchecking the boxes Indicator Stockweigh Link will automatically change this to the indicator model that the most recent data collection w...

Page 32: ...econfigures output format if button depressed while powering ON Don t lay stick reader with button down while applying power Depending on model Allflex Stick Reader gets its power from EID Reader port...

Page 33: ...Enter ON to Enter ON to Enter ON to Enter ON to continue or Press ENTER to continue or Press ENTER to continue or Press ENTER to continue or Press ENTER to reset EID READER reset EID READER reset EID...

Page 34: ...mines new weight quickly This method is for weighing stable loads Lock on Weigh Method 4 Weigh active animals and display stable accurate weight Set to OFF for weighing stable weights Lock On sensitiv...

Page 35: ...T or AUTPRT and PRTFMT set to AUTO standard EZ indicator print format used Print example 09MR04 10 15 880LB GR WTONLY Includes weight display unit if unit is locked on weight tag GR M etc Ends with CR...

Page 36: ...ng information Includes Gross Weight display unit weight tag GR M etc Total Rotation Count Date Time Ends with CR LF Print example 280 LB GR 187 03JL03 3 41P EIDINF Includes EID memory status informat...

Page 37: ...lflex TM Stick Reader user manual for more information C XXXXX X XXX XXXXXXXXXXXX XXXXXX LB GR mm dd yy hh mm Z cr lf Examples of EID print format A 00000 0 982 000017383201 cr lf 890 LB GR 8 27 03 10...

Page 38: ...nnnnnnnnnnnnnnnnnnn C CR LF RS Right Shift 1E hex or 30 decimal EEEEEEEEEEEEEEEEEEEEEEEEEEEEE EID tag 29 alhpanumeric characters vvvvvvv VID tag 7 alphanumeric characters rrrrrrr Group ID 7 alphanumer...

Page 39: ...play data at display rate 6 Transmit numeric display data whenever display weight changes 7 Transmit status data string every second Status data string includes weight rotation counter data date time...

Page 40: ...system s maximum A D counts multiplied by scaling factor Actual weight which over range occurs depends on calibration zero display count size RANGE Under Range Weight on scale system less than minimu...

Page 41: ...entative to install software you do not become owner of Licensed Material according to terms of this agreement License The license granted to you by Digi Star in this agreement authorizes you to use S...

Page 42: ...tial obligation on such valuable information and trade secrets Limited Warranty Digi Star warrants that media on which Software is recorded will be free from defects in workmanship and materials for a...

Page 43: ...nect other load cell to same connector Now stand over second load cell Does it weigh about twice your weight Disconnect first load cell and connect other load cell to same connector Now stand over sec...

Page 44: ...kit Cable Connection Figure 4 Indicator Connection Diagram Rail Mounting Included Wing Mount Included RAM Mount Optional Power Cord See Figure 5 Scale Indicator 12VDC Power Supply Red Terminal Black T...

Page 45: ...Operators Manual D3740 45 Figure 5 Bottom Panel Cable Connections Load Cell Connections Power Cord Connection Allflex TM Stick Reader Computer...

Page 46: ...SW4600EID 46 D3740...

Reviews: