SW4600EID
40 D3740
WEIGHING ERRORS
OVRCAP
Capacity Limit:
Weight on scale system exceeds capacity limit. Capacity value entered in
SETUP to warn of overloading scale system.
+RANGE
Over Range:
Weight on scale system exceeds maximum weight. Over range value
always system’s maximum A/D counts multiplied by scaling factor. Actual
weight which over range occurs depends on calibration, zero, display count
size.
-RANGE
Under Range:
Weight on scale system less than minimum weight. Under range value
always system’s minimum A/D counts multiplied by scaling factor. Actual
weight at which under-range occurs will depend on calibration, zero,
display count size.
Note:
EZII Series supports –RANGE that is equal to +RANGE in absolute
value.