P/N 960-100929R_Rev. 3 {EDP #148849}
© 2012, Japan CashMachine Co., Limited
6 - 7
Calibration and Testing
iVIZION® SeriesNext-Generation Banknote Acceptor Unit
Section 6
Placing the KS-072 Reference Paper
This portion provides information concerning the
KS-072 Reference Paper’s settings and uses.
Perform the following steps to properly place the
KS-072 Calibration Reference Paper into the
iVIZION
®
Device:
1. Open the Upper Guide while pressing in on the
Upper Guide Access Levers located on each side
of the Acceptor Unit that are indicated by the
Blue
Arrows in Figure 6-32a.
2. Place the KS-072 Reference Paper (See Figure 6-
32 b) in the Unit until its Catch Edge reaches
both the left and right side of the Frame
(See Figure 6-32 c).
3. Firmly close the Upper Guide (See Figure 6-33 a)
until it “clicks” into place, and ensure that both
sides are tightly closed and locked in place.
Calibration Procedure
The following two (2) methods exist for perform-
ing each of the iVIZION
®
Calibration Procedures:
•
Calibration Only
•
Calibration plus Serial Number Writing.
C
ALIBRATION
O
NLY
Perform the following steps to just calibrate the
iVIZION
®
Unit Sensors:
1. Turn the iVIZION
®
Unit’s Power Switch
OFF
.
2. Set DIP Switch #8 to
ON
3. Turn the iVIZION
®
Unit’s Power Switch
ON
.
The Status LED will begin flashing and then will
light a steady
Blue
Color.
4. Launch the “
JCM Tool Suite Standard Edition
”
Application. The “
JCM Tool Suite Standard
Edition
” Screen shown in Figure 6-35 will
appear when the application becomes active.
5. Mouse-click on, and hold-down the “
Service
Mode
” Pull-down Menu Selection (See Figure 6-
35 a) and slide-down to select the “
Sensor
Adjustment
” from within the Pull-Down Menu
6. This action will activate the “
iVIZION Calibration
Ver.X.XX
” Mode automatically, and the Screen
shown in Figure 6-36 will appear.
Figure 6-30
Remote Calibration Tools Required
a) iVIZION
®
Device
b) Power Supply
c) PC (OS: Windows XP) (iVIZION USB Driver
Installed)
d) USB Cable
d
1
) USB A Terminal
d
2
) USB Mini-B Terminal
e) Application Software*
(JCM Tool Suite Standard Edition)
f) Reference Paper (KS-072)
*. Contains USB Downloader, Sensor Calibration Performance Test
Programs and Utility.
a
b
d
d
1
d
2
e
f
c
NOTE: Do not touch the Paper Surfaces
of either side of the KS-072 Reference
Paper (See Figure 6-31 a).
Figure 6-31
Reading KS-072 Reference Paper
a
a
Bottom Surface
Top Surface
ID
Sticker
NOTE: Place the KS-072 Reference Paper so
the ID Sticker is visible, otherwise, Calibration
will not be correctly performed.
Figure 6-32
Reference Paper Setting 1
a
b
Open
c
Figure 6-33
Reference Paper Setting 2
a
“Click”
“Click”
Figure 6-34
DIP Switch #8 ON
Figure 6-35
JCM Tool Suite Standard Edition
Screen 3
a
b