NAME: name of sequence
DUP ST: double active step
DEL ST: delete active step
CLEAR: delete whole sequence
SINGLE: displayed inverted: sequence runs only one time
Displayed not inverted: sequence runs as loop and never
stops
LINK F: displayed inverted: fade time in %
Displayed not inverted: fade time in seconds
FADETIME: enter data by means of the left encoder wheel
STEP: choose step by means of the encoder wheel situated in the middle
NEXTTIME: enter data by means of the right encoder wheel
BLOCK: enter block of a number of steps
LINK:
RENUM: Re-numbering of the whole sequence after steps have been inserted
ID: Number half steps
TRIGP: enter trigpoint data by means of the right encoder wheel
14.2 Name sequence
The sequence can be named during the process of storing it.
Press softkey NAME and use keys in Cues/Chases /Sequence section to enter name. To store and leave
function press softkey NAME again.
14.3 Enter duration
Each step can contain data for :
FADETIME: fade in of a step
TRIGPOINT: point at which parameters are going to be switched (only valid for parameters which are not
faded)
NEXTTIME: duration of the whole step
The values can be entered either in seconds or in percents relaying on the nexttime.
It makes sence to enter the values in percent if the sequence runs by manual controlled speed.
Duration of each step