![JB-Lighting licon1 User Manual Download Page 18](http://html1.mh-extra.com/html/jb-lighting/licon1/licon1_user-manual_3491339018.webp)
JB-lighting Lichtanlagen GmbH Sallersteigweg 15 D-89134 Blaustein phone: +49 7304 9617-0
www.jb-lighting.de
- 18 -
The softkeys are named DISP. Partially they can be assigned like described in chapter: Assign midi-notes
with a linked midi-device.
Only the softkeys DISP1, DISP2, DISP3, DISP13, DISP14 and the escape key have to be assigned
differently.
Enter midi-menu by pressing softkey CONFIG/MIDI. Then press one of the midi-keyboards keys. The midi-
note will be shown on the display (e.g. G5). Then press softkey S-KEY to recall the above mentioned keys.
2.7.7 BEATSYNC
Chases and sequences can run on sound-input. If a sequencer is linked to the
Licon1 which is able to send a beatsync signal, they chases and sequences can
run on the beatsync signal instead of the sound signal.
To enter the menu press softkey CONFIG/MIDI. Press softkey BS-ON to
activate beatsync function.
To deactivate beatsync function press softkey BS-OFF.
The display will show the actuall state of the beatsync function.
2.8 ACCESS / Passwords
One master password and
four user passwords with
different authorization can be
activated. First a master
password has to be entered.
Then different profiles can be
assigned to the different
users.
2.8.1 Enter master password
Enter config menu by pressing softkey CONFIG.
Press softkey ACCESS to enter password menu
Enter master passwort first.
Use keys from Cue/Chase/Sequence block.