20
EUROCARGO Euro 6
–
ELECTRONIC SUB-SYSTEMS
ELECTRONIC SUB-SYSTEMS
5.2
BODYBUILDER CONNECTORS
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
Pin
Description
Wire
code
Max.
Load
Connected to
Remarks
8
Warning sound
indicator (EN1501)
6987
1 A
EM X4-01
reserved for IVECO exclusively
Only supported with OPT 6821
Output EN1501 Warning sound indicator
0 V = not engaged
+24V = engaged
9
Keep EM alive
6988
1 A
EM X4-02
0 V = not engaged
+24V = engaged
10
Brake diagnostics lamp
EN1501
6989
1 A
EM X4-03
Only supported w/ opt 6821
Output EN1501 Reverse protections Brake active
0 V = not engaged
+24V = engaged
after K15 active for 2 sec (w/o brake activated)
n.a. when ABS-HSA
(OPT 14861) installed
11
Brake engaged
(EN1501)
6990
1 A
EM X4-21
reserved for IVECO exclusively
Only supported with OPT 6821
Output EN1501 Solenoid Brake
0 V = not engaged
+24V = engaged
12
Neutral gear request
(EN1501)
6991
1 A
EM X4-22
Please contact IVECO for further details
Only supported w/ OPT 6821 & AutoGbx
0 V = not engaged
+24V = engaged
13
Chassis ready (acc.
EN1501)
6992
1 A
EM X4-23
Indicates Chassis Information ready (acc. EN1501)
for adjustment contact IVECO CS organisation
0 V = Off- Frame not ready
+24 V = On - Frame ready
14
Low accelerator pedal
idle switch
6993
1 A
EM X4-31
Indicate that Accelerator pedal idle switch
0 V = OFF - low idle switch not active
+ 24 V = ON - low idle switch active
15
"At least one PTO is
engaged"
6994
1 A
EM X4-32
Indicates at least one PTO is engaged
Signal based on PTO feedback signal/s
0 V = OFF - no PTO engaged
+ 24 V = ON - at least one PTO engaged
16
Bodybuilder fluid level
5981
0-32 V,
0-500
Ohm
(1)
EM X4-14
Analogue input for IC display of Bodybuilder fluid level
(5)
when enabled CANopen 0x6167 n.a.
17
Bodybuilder pressure
5982
0-32 V,
0-500
Ohm
(1)
EM X4-15
Analogue input for IC display of Bodybuilder pressure
(5)
when enabled CANopen 0x6167 n.a.
18
Bodybuilder Thermal
Temperature
5983
0-32 V,
0-500
Ohm
(1)
EM X4-29
Analogue input for IC display of Bodybuilder temperature
(5)
when enabled CANopen 0x6167 n.a.
19
ReGen inhibit
5991
0-2000
Hz
(1)
EM X4-16
reserved for IVECO exclusively
used by IVECO for Cummins application
20
ReGen force
5992
0-2000
Hz
(1)
EM X4-38
reserved for IVECO exclusively
used by IVECO for Cummins application
(1)
During the K15 OFF phase, the input will not be activated so as to avoid an increase in the sleep current.
(2)
Requirements for Functional Safety
Summary of Contents for EUROCARGO
Page 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Page 4: ... Printed 603 95 747 Base 12 2013 ...
Page 6: ... Printed 603 95 747 Base 12 2013 ...
Page 8: ... Printed 603 95 747 Base 12 2013 ...
Page 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Page 10: ... Printed 603 95 747 Base 12 2013 ...
Page 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Page 30: ... Printed 603 95 747 Base 12 2013 ...
Page 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Page 92: ... Printed 603 95 747 Base 12 2013 ...
Page 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Page 136: ... Printed 603 95 747 Base 12 2013 ...
Page 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Page 162: ... Printed 603 95 747 Base 12 2013 ...
Page 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Page 216: ... Printed 603 95 747 Base 12 2013 ...
Page 226: ... Printed 603 95 747 Base 12 2013 ...