EUROCARGO Euro 6
–
ELECTRONIC SUB-SYSTEMS
ELECTRONIC SUB-SYSTEMS
5.2
BODYBUILDER CONNECTORS
15
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
Basic functions of connector 72074 (Allison Automatic transmission)
Pin
Description
Wire
code
Max.
Load
Connected to
Remarks
1
Neutral indicator for
Extra PTO
145
500 mA
ALL 45
Gearbox in neutral.
Ground for neutral engaged.
This output function is activated by the TCM when Neutral is
attained and a programmable combination of engine speed and
transmission output speed has been detected.
2
Multi-state switch
123
15 mA
ALL 23
Limitation 1
st
gear and inhibition reverse gear
Open wire = function active
+24V = function not engaged
Ground = function active
This function is normally enabled with an operator-controlled
momentary switch.
When the function is enabled, the transmission is limited to opera-
tion in only Neutral and (selectable*) low forward range(s).
Operator requests to upshift beyond the maximum* gear range or
to shift into Reverse are ignored by the TCM.
If the function is enabled with Reverse selected on the shift se-
lector, the transmission will shift to Neutral.
If the function is enabled in a forward drive range higher than the
maximum specified gear range*, the TCM will invoke preselect
downshifts until the specified gear range is attained.
The function is disabled when the enabling switch is released.
3
–
142
ALL 42
4
PTO active
143
15 mA
ALL 43
For special applications - Input from PTO switch .
Open wire = inactive
+24V = active
Ground = inactive
Enabling this function alerts the TCM that PTO operation has been
requested by the operator.
When the input function is enabled, the TCM disrupts the “modu-
lated main pressure” feature in the transmission, resulting in trans-
mission operation at full main pressure.
When the function is enabled and all of the following conditions
exist, the TCM activates Output Function G (PTO Enable Output).
Required operating conditions for enabling of this function are:
●
accelerator position is "low";
●
engine speed and output speed are within Customer Modifi-
able Constant limits.
5
PTO control
130
500 mA
ALL 30
For special applications - 24V output to activate the PTO
This output function is activated when use of the PTO has been
requested and all operating conditions required to enable the PTO
have been satisfied.
6
Reserved
7
Reserved
Summary of Contents for EUROCARGO
Page 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Page 4: ... Printed 603 95 747 Base 12 2013 ...
Page 6: ... Printed 603 95 747 Base 12 2013 ...
Page 8: ... Printed 603 95 747 Base 12 2013 ...
Page 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Page 10: ... Printed 603 95 747 Base 12 2013 ...
Page 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Page 30: ... Printed 603 95 747 Base 12 2013 ...
Page 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Page 92: ... Printed 603 95 747 Base 12 2013 ...
Page 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Page 136: ... Printed 603 95 747 Base 12 2013 ...
Page 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Page 162: ... Printed 603 95 747 Base 12 2013 ...
Page 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Page 216: ... Printed 603 95 747 Base 12 2013 ...
Page 226: ... Printed 603 95 747 Base 12 2013 ...