14
EUROCARGO Euro 6
–
POWER TAKE-OFFS
POWER TAKE-OFFS
4.6
PTO MANAGEMENT
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
Table 4.5
Button
Function
RES / OFF
Activate/deactivate intermediate engine speed. The factory intermediate engine speed
setting is 900 rpm, which may be altered by the driver.
SET+ / SET-
Increase/reduce active intermediate engine speed setting
Accelerator pedal
Active
Max. rpm possible with SET+ button or accelerator pedal
N
LL
(1)
÷ maximum rpm permitted by engine
Torque delivered
Maximum specific engine torque
Conditions for deactivating intermediate engine speed function
●
Operation of the brake or clutch pedal
●
CC Off activated
●
engine brake operated
●
lntarder operated
●
PTO mode 0 deactivation speed
●
'NEUTRAL' not selected (automatic transmissions)
(1)
N
LL
= rpm at idle speed.
PTO modes 1, 2, 3 (configurable)
Three different and independent PTO maps may be programmed on the electronic control units by IVECO Service. The engine
can, of course, only operate with one PTO mode at a time. The following priorities are assigned to the modes:
●
PTO mode 3: high priority;
●
PTO mode 2: medium priority;
●
PTO mode 1: low priority;
●
PTO mode 0: driving mode.
Note
The Bodybuilder must observe this order of priority when managing the outfitting and interface outfitting. This is so as to avoid
additional costs for subsequent modifications to the wiring or reprogramming.
The following table shows the parameters making up a PTO mode. These parameters may only be programmed by IVECO Service
using an EASY diagnostic station.
Table 4.6
Parameter
Possible values
Max. rpm possible with SET + button N
SET_max
(9)
N
LL
÷ N
max
(2)
Maximum rpm possible with accelerator pedal
N
max_acc
Engine rpm increment with SET + button
250 rpm for each second button is pressed
Engine rpm decrement with SET - button
As above
Torque limiting
(3)
See table
Overspeed regulator curve gradient
"High Idle" curve: vertical by default
Usage of CC buttons (RES / OFF / SET + / SET-)
Active / inactive
Storing intermediate engine speed setting
Fixed (EASY)/free (driver)
(8)
'TIP' function for SET + / SET- buttons
(4)
Active / inactive
PTO mode deactivated with brake or clutch (independently for each mode)
(5)
Active / inactive
Accelerator pedal
Active / inactive
Recalling stored intermediate engine speed setting with RES after activation of PTO
mode
(7)
Active / inactive
Minimum rpm value settable with SET - button. N
SET _min
(9)
> 500 rpm
Summary of Contents for EUROCARGO
Page 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Page 4: ... Printed 603 95 747 Base 12 2013 ...
Page 6: ... Printed 603 95 747 Base 12 2013 ...
Page 8: ... Printed 603 95 747 Base 12 2013 ...
Page 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Page 10: ... Printed 603 95 747 Base 12 2013 ...
Page 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Page 30: ... Printed 603 95 747 Base 12 2013 ...
Page 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Page 92: ... Printed 603 95 747 Base 12 2013 ...
Page 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Page 136: ... Printed 603 95 747 Base 12 2013 ...
Page 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Page 162: ... Printed 603 95 747 Base 12 2013 ...
Page 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Page 216: ... Printed 603 95 747 Base 12 2013 ...
Page 226: ... Printed 603 95 747 Base 12 2013 ...