EUROCARGO Euro 6
–
CHASSIS INTERVENTIONS
CHASSIS INTERVENTIONS
2.11
INSTALLING AN ADDITIONAL HEATING SYSTEM
45
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
●
check that, with thermostat open and engine running idle, that average pressure in the water pump outlet pipe is greater than
500 mm water column.
2.11
INSTALLING AN ADDITIONAL HEATING SYSTEM
We recommend using IVECO type heating systems whenever it is necessary to install an additional heating system.
On vehicles where IVECO does not employ these heaters, installation must be done in compliance with the instructions issued by
the equipment Manufacturer (installation of heaters, pipes, electric system, etc.) and in relation to the following indications.
The additional heating system must respect all national standards on the subject (e.g. tests, specific installations for the transport of
hazardous materials, etc.). It must avoid the use of vehicle equipment that requires certified approval whenever such equipment
may cause a negative impact on performance.
In addition, be sure to:
●
care for the proper operation of all other vehicle systems (e.g.: engine cooling system);
●
check that the battery capacity and alternator power are sufficient for increased current draw (see Chapter 5.7 (
➠
Page 36))
and install a protection fuse on the new circuit;
●
connect - for the fuel supply - the supply system to a supplementary tank that is installed along the return pipe of the engine
fuel. Direct connection to the vehicle tank is allowed under the condition that it occurs independently from the engine fuel
supply, and the new circuit must be perfectly airtight;
●
route piping and wiring layout (and installation of brackets and flexible fittings) in relation to the spaces available and the influ-
ence of heat on the chassis parts. Avoid any exposed parts that may be dangerous, and adopt suitable guards when necessary.
The system must allow easy access and prompt maintenance.
The Bodybuilder must provide all necessary maintenance instructions.
a)
Water heaters
When the original vehicle heating and engine cooling circuits are involved (see Chapter 2.10 (
➠
Page 44)), the following must be
done to ensure good system operation and safety of the original system:
●
carefully define the connection points between the additional and original systems, in agreement with IVECO, if necessary.
The added pipes must be made of brass or other alloy resistant to the corrosive action of coolant, the coupling sleeves must
respect the requirements put forth by the standard IVECO 18-0400;
●
plan for a rational layout of pipes, avoiding bottlenecks and siphoning bends;
●
install venting valves (bleed points) to allow proper system filling;
●
allow complete circuit discharge, also by installing any additional plugs;
●
adopt, when necessary, suitable protections to limit heat loss.
b)
Air heaters
As regards these heaters and for direct cab installation, be particularly cautious with the exhausts (to avoid combustion gasses from
being trapped in the vehicle) and correct distribution of hot air (in order to avoid direct flow).
Summary of Contents for EUROCARGO
Page 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Page 4: ... Printed 603 95 747 Base 12 2013 ...
Page 6: ... Printed 603 95 747 Base 12 2013 ...
Page 8: ... Printed 603 95 747 Base 12 2013 ...
Page 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Page 10: ... Printed 603 95 747 Base 12 2013 ...
Page 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Page 30: ... Printed 603 95 747 Base 12 2013 ...
Page 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Page 92: ... Printed 603 95 747 Base 12 2013 ...
Page 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Page 136: ... Printed 603 95 747 Base 12 2013 ...
Page 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Page 162: ... Printed 603 95 747 Base 12 2013 ...
Page 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Page 216: ... Printed 603 95 747 Base 12 2013 ...
Page 226: ... Printed 603 95 747 Base 12 2013 ...