EUROCARGO Euro 6
–
ELECTRONIC SUB-SYSTEMS
ELECTRONIC SUB-SYSTEMS
5.7
ELECTRICAL SYSTEM: CURRENT INTERVENTIONS AND DRAWS
53
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
(1)
For uses of more than 30 seconds.
(2)
Depending on the position and therefore the temperature that may be reached in the housing, choose fuses that can be loaded
to up to 70%- 80% of their maximum capacity.
▶
The fuse must be connected as close as possible to the current take-off point.
Precautions
●
Incorrect installation of electrical accessories may affect occupant safety and cause severe damage to the vehicle.
Contact IVECO if you have any questions.
●
Avoid coupling with signal transmission cables (e.g. ABS), for which a preferential path has been defined for electromagnetic
requirements (EMI).
It should be noted that when grouping several cables together, in order to compensate for lower heat dispersal capacity, the
current intensity must be reduced with respect to the nominal value of a single cable.
●
In vehicles with frequent engine start-ups, with limited current drawn and engine rotations (e.g.vehicles with refrigeration
chambers), provide for periodic battery charging to maintain efficiency.
●
Plug and terminal connections must be protected, resistant to weathering, and executed using components of the same type
as those utilised originally on the vehicle.
●
In the event that a component has to be installed just next to the route of a cable belonging to the original system, make sure
that its remains integral and avoid any cuts.
▶
Any damage caused by failure to comply with procedure is not covered by warranty.
Modifying wheelbase and overhang
Should it be necessary to lengthen the wires on the chassis owing to the new dimensions of wheelbase and overhang, a watertight
junction box must be used which has the same characteristics as those used on the standard vehicle. The electrical components
used such as wires, connectors, terminal blocks, conduits etc. must be of the same type as those used originally and must be cor-
rectly fitted.
Side Marker Lamp installation
EC regulations require that vehicles are provided with side and clearance lights when the total length exceeds 6 m.
The installation of the lateral lights must be performed on the additional structure (containers, vans, etc.), while the electric power
supply must be obtained by the specific connector 61069 on the chassis (see Fig. 5.39).
Note
It is not possible to draw current from side marker lights.
Summary of Contents for EUROCARGO
Page 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Page 4: ... Printed 603 95 747 Base 12 2013 ...
Page 6: ... Printed 603 95 747 Base 12 2013 ...
Page 8: ... Printed 603 95 747 Base 12 2013 ...
Page 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Page 10: ... Printed 603 95 747 Base 12 2013 ...
Page 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Page 30: ... Printed 603 95 747 Base 12 2013 ...
Page 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Page 92: ... Printed 603 95 747 Base 12 2013 ...
Page 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Page 136: ... Printed 603 95 747 Base 12 2013 ...
Page 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Page 162: ... Printed 603 95 747 Base 12 2013 ...
Page 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Page 216: ... Printed 603 95 747 Base 12 2013 ...
Page 226: ... Printed 603 95 747 Base 12 2013 ...