12
EUROCARGO Euro 6
–
ELECTRONIC SUB-SYSTEMS
ELECTRONIC SUB-SYSTEMS
5.2
BODYBUILDER CONNECTORS
–
Printed 603.95.747
–
1st Ed. - Base 12/2013
Pin
Description
Wire
code
Max.
Load
Connected to
Remarks
9
Gearbox neutral
8050
200 mA
VCM X1-07
EM X1-07
0 V = neutral not engaged
+24 V = neutral engaged
Input driven by EM, when installed
Else input driven by VCM
10
Reverse gear
2268
200 mA
IBC3 E-16
0 V = reverse gear not engaged
+24 V = reverse gear engaged
11
K15
8871
5 A
IBC3 B-01
K15
(after fuse)
12
CC Set+
8156
10 mA
VCM X3-33
Input signal
(2)
Open wire = Set + not activated
Ground = Set+ activated
13
CC Set-
8157
10 mA
VCM X3-32
Input signal
(2)
Open wire = Set - not activated
Ground = Set - activated
14
CC OFF
8154
10 mA
VCM X3-30
Input signal
(2)
Open wire = Off not activated
Ground = OFF activated
15
CC Resume
8155
10 mA
VCM X3-31
Input signal
(2)
Open wire = RES not activated
Ground = RES activated
16
CC Driver/BB
0152
10 mA
VCM X3-49
CC activation by Driver or Bodybuilder (BB)
Open wire = CC controlled by driver
Connected to ground = CC controlled by Bodybuilder (BB)
17
Ground
0000
10 A
Wiring
Ground
18
PTO 1 sw
0131
10 mA
VCM X3-47
EM X3-5
Input signal
(3)
Open wire = PTO mode 1 not activated
Ground = PTO mode 1 activated
Input driven by EM, when installed
Else input driven by VCM
19
PTO 2 sw
0132
10 mA
VCM X3-46
EM X3-6
Input signal
(3)
Open wire = PTO mode 2 not activated
Ground = PTO mode 2 activated
Input driven by EM, when installed
Else input driven by VCM
20
PTO 3 sw
0123
10 mA
VCM X3-45
EM X3-7
Input signal
(3)
Open wire = PTO mode 3 not activated
Ground = PTO mode 3 activated
Input driven by EM, when installed
Else input driven by VCM
21
K30
7772
10 A
IBC3 B-09
K30 (after fuse)
(4)
(1)
Tachograph B7 Signal
Parameter
Min
Typ
Max
Unit
Remarks
Voltage U
low
1,5
V
I = 1 mA
Voltage U
high
5,5
V
I = -1 mA
Frequency
<1,6
kHz
Square wave
Pulse duration
0,64
2
4
ms
The Tachograph B7 output provides the speed pulse according to ISO16844-2.
Summary of Contents for EUROCARGO
Page 1: ...EUROCARGO EURO 6 M E D I U M R A N G E BODYBUILDERS INSTRUCTIONS ISSUE 2013 ...
Page 4: ... Printed 603 95 747 Base 12 2013 ...
Page 6: ... Printed 603 95 747 Base 12 2013 ...
Page 8: ... Printed 603 95 747 Base 12 2013 ...
Page 9: ... Printed 603 95 747 Base 12 2013 SECTION 1 GENERAL INFORMATION ...
Page 10: ... Printed 603 95 747 Base 12 2013 ...
Page 29: ... Printed 603 95 747 Base 12 2013 SECTION 2 CHASSIS INTERVENTIONS ...
Page 30: ... Printed 603 95 747 Base 12 2013 ...
Page 91: ... Printed 603 95 747 Base 12 2013 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES ...
Page 92: ... Printed 603 95 747 Base 12 2013 ...
Page 135: ... Printed 603 95 747 Base 12 2013 SECTION 4 POWER TAKE OFFS ...
Page 136: ... Printed 603 95 747 Base 12 2013 ...
Page 138: ...4 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 160: ...26 EUROCARGO Euro 6 POWER TAKE OFFS POWER TAKE OFFS Printed 603 95 747 1st Ed Base 12 2013 ...
Page 161: ... Printed 603 95 747 Base 12 2013 SECTION 5 ELECTRONIC SUB SYSTEMS ...
Page 162: ... Printed 603 95 747 Base 12 2013 ...
Page 215: ... Printed 603 95 747 Base 12 2013 SECTION 6 SPECIAL INSTRUCTIONS FOR SCR EXHAUST SYSTEM ...
Page 216: ... Printed 603 95 747 Base 12 2013 ...
Page 226: ... Printed 603 95 747 Base 12 2013 ...