P07.02
QUICK/JOG
key function
selection
0: No function
1: Jog
2: Switch between states
3: Switch between forward and
reverse rotating
4: Clear the UP/DOWN setting
5: Coast to stop
6: Switch command channels in
sequence
7: Quick commissioning mode
(based on non-factory parameter
settings)
0
–7
1
◎
P07.03
Sequence of switching
running-command channels
by pressing QUICK
0:
Keypad→Terminal→Communica
tion
1: Keypad←→Terminal
2: Keypad←→Communication
3: Terminal←→Communication
0
–3
0
○
P07.04
Stop function validity of
STOP/RST
0: Valid only for keypad control
1: Valid both for keypad and
terminal control
2: Valid both for keypad and
communication control
3: Valid for all control modes
0
–3
0
○
P07.05
Selection 1 of parameters to
be displayed in the running
state
0x0000
–0xFFFF
BIT0: Running frequency (Hz on)
BIT1: Set frequency (Hz blinking)
BIT2: Bus voltage (V on)
BIT3: Output voltage (V on)
BIT4: Output current (A on)
BIT5: Running speed (rpm on)
Bit 6: Output power (% on)
Bit 7: Output torque (% on)
Bit 8: PID reference value (%
blinking)
Bit 9: PID feedback value (% on)
BIT10: Input terminal status
BIT11: Output terminal status
Bit 12: Set torque (% on)
Bit 13: Pulse count value
Bit 14: Length value
Bit 15: PLC and current step
number of multi-step speed
0x0000
–
0xFFFF
0x03FF
○
P07.06
Selection 2 of parameters to
be displayed in the running
state
0x0000
–0xFFFF
Bit 0: AI1 (V on)
Bit 1: AI1 (V on)
Bit 2: AI3 (V on)
BIT3: HDI frequency
0x0000
–
0xFFFF
0x0000